VxRail 2: Node Robo Cluster Shutdown Best Practice

Oversigt: This article describes the best practice for VxRail 2 node ROBO cluster shutdown.

Denne artikel gælder for Denne artikel gælder ikke for Denne artikel er ikke knyttet til et bestemt produkt. Det er ikke alle produktversioner, der er identificeret i denne artikel.

Instruktioner

The instructions only apply to the VxRail 2 node ROBO cluster. 

VxRail Manager does not handle VSAN witness host during the cluster shutdown and startup process. 

To shut down the VxRail 2 node ROBO cluster, follow the following steps.

Cluster shutdown  
  1. From VxRail UI, initialize cluster shutdown. Follow the wizard to proceed. The two physical VxRail hosts power off. 
  2. VxRail does not handle Witness. It is required to manually be placed into maintenance mode with no data migration option, and powered off.
Cluster startup
  1. Power on witness host and exit from maintenance mode at first. This is important. Otherwise, VSAN cluster may suffer temporary partition until witness host is ready.
  2. Observed witness host is ready. Power on the two VxRail physical hosts.
  3. You may have to manually enable HA and power on VxRail system VMs if VSAN objects are not back into healthy state in 5 minutes.