Dell Command Powershell Provider Software Error with the Latitude 7420

Oversigt: Information about an issue with Dell Command | PowerShell Provider (DCPP) version 2.7.2.1 failing when attempting to import the DellBIOSProvider module on to a Latitude 7420.

Denne artikel gælder for Denne artikel gælder ikke for Denne artikel er ikke knyttet til et bestemt produkt. Det er ikke alle produktversioner, der er identificeret i denne artikel.

Symptomer

Affected Platforms:

  • Latitude 7420

Affected Products:

  • Dell Command | PowerShell Provider

When the command import-module DellBIOSProvider verbose is run, it fails once it reaches the line showing:

Performing operation New-PSDrive for the provider DellSmbiosProv

With an error stating:-

Unhandled Exception: System.AccessViolationException: Attempted to read or write protected memory. This is often an indication that other memory is corrupt.

Årsag

The issue has been root caused to a specific attribute in DCPP version 2.7.2.1 and earlier versions.

Løsning

Update the DCPP software to version 2.9.0.69, A00 or later to resolve this issue.