PowerFlex: SO Node deployment fails as the OS repository is missing DellEMCPowerFlexEMbeddedOS2
Oversigt: Storage Only (SO) Node Deployment fails as the OS repository is missing on the MVMs after a resynchronization.
Denne artikel gælder for
Denne artikel gælder ikke for
Denne artikel er ikke knyttet til et bestemt produkt.
Det er ikke alle produktversioner, der er identificeret i denne artikel.
Symptomer
SO node deployment fails after a resynchronization of the repository. New OS directories are created, and the expected OS directory is not available on the MVMs.
Årsag
-
DellEMC PowerFlex EMbeddedOS 3 (RHEL) and DellEMC PowerFlex EMbeddedOS 4 (SUSE) were created after a resync.

- PowerFlex Manager was trying to deploy using DellEMC PowerFlex EMbeddedOS 2 (SUSE)
-
In
/opt/platfrom/fileshare/[deploymentID]/on each MVM the DellEMCPowerFlexEMbeddedOS2 is no longer available.
Løsning
Create the directory and copy the contents from the required repository and retry the deployment. As this was a SUSE deployment, The neeeded files are from DellEMCPowerFlexEMbeddedOS4.
Example:
cp -r DellEMCPowerFlexEMbeddedOS4 DellEMCPowerFlexEMbeddedOS2
Berørte produkter
PowerFlex rack, PowerFlex Appliance, PowerFlex custom node, PowerFlex custom nodeArtikelegenskaber