PowerScale: Isilon: LCD panel node number does not update when a node is renumbered using lnnset

Summary: The LCD panel on a node will continue to display the old node number after the node is renumbered using the 'lnnset' command in 'isi config'. An update must be triggered to force the LCD panel to display the proper node number. ...

Αυτό το άρθρο ισχύει για Αυτό το άρθρο δεν ισχύει για Αυτό το άρθρο δεν συνδέεται με κάποιο συγκεκριμένο προϊόν. Δεν προσδιορίζονται όλες οι εκδόσεις προϊόντων σε αυτό το άρθρο.

Symptoms

The logical node number (LNN) of an Isilon node can be changed using the 'lnnset' command inside the 'isi config' tool. Although the change takes effect immediately, the LCD front panel of the node continues to show the old node number.

Cause

The lnnset command does not notify the LCD control daemon that a change has occurred, so the daemon is not aware that an update is needed.

Resolution

The LCD daemon must be triggered to update LCD information in order for the front panel display to pick up the change. Use any of the following methods to update the LCD information:

1. Restart the LCD daemon to update the LCD panel using the following command:
 
# isi_lcd_d restart


2. Instruct the LCD daemon to reset and update the LCD panel using the following command:
 
# killall -HUP isi_lcd_d


3. Remove the front panel from the node, wait 30 s, and then reseat it. The front panel display may take up to 60 s to start up. When finished, it should light up and display the new node number.

4. Reboot the node.

Επηρεαζόμενα προϊόντα

PowerScale OneFS

Προϊόντα

PowerScale OneFS
Ιδιότητες άρθρου
Article Number: 000015082
Article Type: Solution
Τελευταία τροποποίηση: 27 Φεβ 2025
Version:  6
Βρείτε απαντήσεις στις ερωτήσεις σας από άλλους χρήστες της Dell
Υπηρεσίες υποστήριξης
Ελέγξτε αν η συσκευή σας καλύπτεται από τις Υπηρεσίες υποστήριξης.