NetWorker: v9.0 VMware-töitä ei voi kloonata CloudBoost-laitteeseen

Summary: VMware vProxyn tallennusjoukkojen kloonaus CloudBoostiin epäonnistuu. Virheelliset tallennusjoukon tunnukset, ei työkohteita, virhe: pooli tuetuilla solmuilla; Syy: solmuversio 9.1.

Αυτό το άρθρο ισχύει για Αυτό το άρθρο δεν ισχύει για Αυτό το άρθρο δεν συνδέεται με κάποιο συγκεκριμένο προϊόν. Δεν προσδιορίζονται όλες οι εκδόσεις προϊόντων σε αυτό το άρθρο.

Symptoms

 

VMware-varmuuskopioiden (vProxy-varmuuskopiointi) tallennusjoukkojen kloonaus CloudBoost-laitteeseen epäonnistuu.

mm/dd/yyyy hh:mm:ss meridiem Following savesets will be skipped please make sure saveset id is valid and target pool is valid
<SSID>
mm/dd/yyyy hh:mm:ss meridiem failed to get mmd reservation with err: There are no savesets to clone, mmd reservation is skipped. .
mm/dd/yyyy hh:mm:ss meridiem Unable to update '<SSID(53>/' status. Error: Work item <SSID(53)>/ not found in running list.
mm/dd/yyyy hh:mm:ss meridiem Unable to set work item status for all failed save sets
mm/dd/yyyy hh:mm:ss meridiem No valid input savesets - check CLONE SKIPPED SAVESETS!
mm/dd/yyyy hh:mm:ss meridiem No valid backend job
mm/dd/yyyy hh:mm:ss meridiem   [ORIGINAL REQUESTED SAVESETS]
mm/dd/yyyy hh:mm:ss meridiem <SSID(53)>/;
mm/dd/yyyy hh:mm:ss meridiem   [CLONE SKIPPED SAVESETS]
mm/dd/yyyy hh:mm:ss meridiem <SSID>, <SSID>/<CLONE_ID>;
mm/dd/yyyy hh:mm:ss meridiem Action clone 'clone' with job id <JOB_ID_number> is exiting with status 'failed', exit code 1
mm/dd/yyyy hh:mm:ss meridiem NSRCLONE failed for one or more savesets.

Virheen daemon-lokin < tarkastelu virheen hetkellä kk/pp/vv hh:mm:ss meridiem> löytää viestin:

71193 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Protection Policy Notice: Starting action '<Action_name>' for workflow '<Policy_name>/<Workflow_name>'
165718 mm/dd/yyyy hh:mm:ss meridiem  5 5 0 109037312 29038 0 <NetWorker_Server_name> nsrd NSR critical Unable to clone save set with ID '<SSID>': The '<Pool_name>' pool includes incompatible storage nodes: Ensure that you upgrade the following storage nodes to version 9.1 or later: <CloudBoost_Storage_Node_name>.
71193 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Error Alert: Clone operation failed with error: 'NSRCLONE failed for one or more savesets. '.
38758 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: action clone failed
38758 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: workflow <Workflow_name> failed
89017 mm/dd/yyyy hh:mm:ss meridiem  1 5 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR notice Scheduled resource list: NSR Protection Policy <Policy_name> exited with return code 1.
 



 

Cause

Pyydä parannusta. Tunnettu ongelma: NW-I-404: NetWorker: Kloonaus vProxy-tallennusjoukoilla CloudBoost-laitteeseen.

Resolution

Tuotehallinta tutkii parannuspyyntöä. Pyyntöä käsitellään edelleen. Ota yhteyttä asiakastukikeskukseen saadaksesi apua ja mainitse tämän artikkelin numero.

TILAPÄISRATKAISU: Kun käytössä on NetWorker 9.0.1 tai uudempi tietovyöhyke, määritä ulkoinen tallennussolmu. Katso NetWorker 9.1 CloudBoost 2.1 Integration Guide -oppaan osasta NetWorker 9.1: Laitteen määrittäminen käyttämällä ulkoista tallennussolmua CloudBoostia varten".

Επηρεαζόμενα προϊόντα

Cloud Backup & Protection, NetWorker
Ιδιότητες άρθρου
Article Number: 000065416
Article Type: Solution
Τελευταία τροποποίηση: 04 Δεκ 2025
Version:  5
Βρείτε απαντήσεις στις ερωτήσεις σας από άλλους χρήστες της Dell
Υπηρεσίες υποστήριξης
Ελέγξτε αν η συσκευή σας καλύπτεται από τις Υπηρεσίες υποστήριξης.