NetWorker: v9.0 VMware İşleri CloudBoost Aygıtına klonlanamıyor
Summary: VMware vProxy kayıt setlerini CloudBoost a klonlama işlemi başarısız oluyor. Hatalı kayıt kümesi kimlikleri, iş öğesi yok, hata: desteklenmeyen düğümlere sahip havuz; Neden: Düğüm sürümü 9.1. ...
Αυτό το άρθρο ισχύει για
Αυτό το άρθρο δεν ισχύει για
Αυτό το άρθρο δεν συνδέεται με κάποιο συγκεκριμένο προϊόν.
Δεν προσδιορίζονται όλες οι εκδόσεις προϊόντων σε αυτό το άρθρο.
Symptoms
VMware yedekleri (vProxy yedekleme) kaydetme kümelerini bir CloudBoost aygıtına klonlama işlemi başarısız oluyor.
mm/dd/yyyy hh:mm:ss meridiem Following savesets will be skipped please make sure saveset id is valid and target pool is valid <SSID> mm/dd/yyyy hh:mm:ss meridiem failed to get mmd reservation with err: There are no savesets to clone, mmd reservation is skipped. . mm/dd/yyyy hh:mm:ss meridiem Unable to update '<SSID(53>/' status. Error: Work item <SSID(53)>/ not found in running list. mm/dd/yyyy hh:mm:ss meridiem Unable to set work item status for all failed save sets mm/dd/yyyy hh:mm:ss meridiem No valid input savesets - check CLONE SKIPPED SAVESETS! mm/dd/yyyy hh:mm:ss meridiem No valid backend job mm/dd/yyyy hh:mm:ss meridiem [ORIGINAL REQUESTED SAVESETS] mm/dd/yyyy hh:mm:ss meridiem <SSID(53)>/; mm/dd/yyyy hh:mm:ss meridiem [CLONE SKIPPED SAVESETS] mm/dd/yyyy hh:mm:ss meridiem <SSID>, <SSID>/<CLONE_ID>; mm/dd/yyyy hh:mm:ss meridiem Action clone 'clone' with job id <JOB_ID_number> is exiting with status 'failed', exit code 1 mm/dd/yyyy hh:mm:ss meridiem NSRCLONE failed for one or more savesets.
Hatanın mm/gg/yyyy ss:dd:ss meridiem şu mesajı bulduğunda daemon> günlüğünün < gözden geçirilmesi:
71193 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Protection Policy Notice: Starting action '<Action_name>' for workflow '<Policy_name>/<Workflow_name>' 165718 mm/dd/yyyy hh:mm:ss meridiem 5 5 0 109037312 29038 0 <NetWorker_Server_name> nsrd NSR critical Unable to clone save set with ID '<SSID>': The '<Pool_name>' pool includes incompatible storage nodes: Ensure that you upgrade the following storage nodes to version 9.1 or later: <CloudBoost_Storage_Node_name>. 71193 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Error Alert: Clone operation failed with error: 'NSRCLONE failed for one or more savesets. '. 38758 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: action clone failed 38758 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: workflow <Workflow_name> failed 89017 mm/dd/yyyy hh:mm:ss meridiem 1 5 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR notice Scheduled resource list: NSR Protection Policy <Policy_name> exited with return code 1.
Cause
Geliştirme Talebi. Bilinen sorun: NW-I-404: NetWorker: vProxy kaydetme kümelerini bir CloudBoost Cihazına klonlama.
Resolution
Ürün Yönetimi bu iyileştirme isteğini araştırıyor. İstek hala devam ediyor. Yardım için Müşteri Destek Merkezi ile iletişime geçin ve bu makale numarasını belirtin.
GEÇICI ÇÖZÜM: NetWorker 9.0.1 veya üzeri veri bölgesiyle harici bir depolama düğümü yapılandırın. "NetWorker 9.1 CloudBoost 2.1 Entegrasyon Rehberi"nin "NetWorker 9.1: CloudBoost için harici bir depolama düğümü kullanarak bir aygıtı yapılandırma".
GEÇICI ÇÖZÜM: NetWorker 9.0.1 veya üzeri veri bölgesiyle harici bir depolama düğümü yapılandırın. "NetWorker 9.1 CloudBoost 2.1 Entegrasyon Rehberi"nin "NetWorker 9.1: CloudBoost için harici bir depolama düğümü kullanarak bir aygıtı yapılandırma".
Επηρεαζόμενα προϊόντα
Cloud Backup & Protection, NetWorkerΙδιότητες άρθρου
Article Number: 000065416
Article Type: Solution
Τελευταία τροποποίηση: 04 Δεκ 2025
Version: 5
Βρείτε απαντήσεις στις ερωτήσεις σας από άλλους χρήστες της Dell
Υπηρεσίες υποστήριξης
Ελέγξτε αν η συσκευή σας καλύπτεται από τις Υπηρεσίες υποστήριξης.