Symptoms

Durante um upgrade do código do PowerStoreOS, a verificação de integridade pré-upgrade apresentou falha.
PUHC Fail - The system encountered unexpected backend errors.

 

Cause

No log de registro do nó do PowerStore, a causa é registrada.

Sep 28 22:56:54.847708 ASSET-A control-path[124493]: 2021-09-28 22:56:54.847 [NDU] [INFO] [com.emc.cyclone.contexts.infrastructure.ndu.application.NDUCommonUtil.ApplianceUpgradeUtil|vert.x-eventloop-thread-0] [72fee6ed-bc69-47f6-a4e3-05d8ac9deb1d|9b3b14a3-e90d-4fee-914d-1ac253b28bb1|fetchApplianceSessionInfo] Platform request to fetch appliance session id completed successfully1
 Sep 28 22:56:54.847772 ASSET-A control-path[124493]: 2021-09-28 22:56:54.847 [NDU] [INFO] [com.emc.cyclone.contexts.infrastructure.ndu.application.NDUCommonUtil.ApplianceUpgradeUtil|vert.x-eventloop-thread-0] [72fee6ed-bc69-47f6-a4e3-05d8ac9deb1d|9b3b14a3-e90d-4fee-914d-1ac253b28bb1|fetchApplianceSessionInfo] Is rollback failed state on the appliance upgrade session is null
 Sep 28 22:56:54.954970 ASSET-A control-path[124493]: 2021-09-28 22:56:54.954 [NDU] [INFO] [com.emc.cyclone.contexts.infrastructure.ndu.application.NDUCommonUtil.AwaitResponsesFromPlatformUtil|vert.x-eventloop-thread-0] [72fee6ed-bc69-47f6-a4e3-05d8ac9deb1d|9b3b14a3-e90d-4fee-914d-1ac253b28bb1|prestageHandleResponse] Platform request completed successfully
 Sep 28 22:57:24.996368 ASSET-A control-path[124493]: 2021-09-28 22:57:24.996 [NDU] [ERROR] [com.emc.cyclone.contexts.infrastructure.services.platform.gateway.application.upgrade.service.cycloneCommandService.PrestageUpgradePackageAS|vert.x-eventloop-thread-0] [72fee6ed-bc69-47f6-a4e3-05d8ac9deb1d]
 Prestage failed: (with error 'java.lang.Exception: ERROR: 15G free space is required. Clean up the space under /cyc_cfs and try again.

Explicação
O cyc_fs file system é usado para armazenar arquivos de diagnóstico de materiais de suporte, e o espaço consumido por eles normalmente é gerenciado automaticamente. Em algumas raras ocasiões, muitos materiais de suporte foram retidos, fazendo com que o espaço livre no cyc_fs fosse baixo.

 

Resolution

Use a interface do usuário do PowerStore Manager ou o svc_dc de script do shell de serviço para remover coletas de dados mais antigas para liberar espaço no cyc_fs.

 

Επηρεαζόμενα προϊόντα

PowerStore 1000T

Προϊόντα

PowerStore, PowerStore 3000T, PowerStore 5000T, PowerStore 9000T
Ιδιότητες άρθρου
Article Number: 000192404
Article Type: Solution
Τελευταία τροποποίηση: 16 Ιαν 2026
Version:  4
Βρείτε απαντήσεις στις ερωτήσεις σας από άλλους χρήστες της Dell
Υπηρεσίες υποστήριξης
Ελέγξτε αν η συσκευή σας καλύπτεται από τις Υπηρεσίες υποστήριξης.