NetWorker VMware Protection vProxy: VM snapshot creation incomplete: An error occurred while taking a snapshot: Invalid change tracker error code

Summary: Dell NetWorker vProxy backup for a VM fails due to failing VMware snapshot. ERROR: Snapshot creation task failed: An error occurred while taking a snapshot: Invalid change tracker error code ...

Αυτό το άρθρο ισχύει για Αυτό το άρθρο δεν ισχύει για Αυτό το άρθρο δεν συνδέεται με κάποιο συγκεκριμένο προϊόν. Δεν προσδιορίζονται όλες οι εκδόσεις προϊόντων σε αυτό το άρθρο.

Symptoms

VM backups performed through the NetWorker VMware Protection (NVP) vProxy appliance fail

The vProxy log reports:
/opt/emc/vproxy/runtime/logs/vbackupd/vbackupd-snapmgr.log

2023-02-28T01:24:10Z INFO: Connected to session on vCenter 'vcenter.local' Version '7.0.3 build-20845200, API:7.0.3.0', Uuid:#.
2023-02-28T01:24:10Z INFO: Creating snapshot type 'COPY' with timeout of 30 minutes ...
2023-02-28T01:24:10Z NOTICE: Snapshot free space threshold validation not requested.
2023-02-28T01:24:10Z INFO: Found virtual machine 'VMname' with MORef 'vm-#'.
2023-02-28T01:24:10Z INFO: Host 'esxihost.local' is running 7.0.3.
2023-02-28T01:24:10Z INFO: host version 7.0.3:true
2023-02-28T01:24:11Z ERROR: Snapshot creation task failed: An error occurred while taking a snapshot: Invalid change tracker error code.
2023-02-28T01:24:11Z ERROR: Unable to create quiesced snapshot: An error occurred while taking a snapshot: Invalid change tracker error code.
2023-02-28T01:24:11Z NOTICE: Snapshot free space threshold validation not requested.
2023-02-28T01:24:11Z WARN: Retrying as a non-quiesced snapshot: Unable to create quiesced snapshot: An error occurred while taking a snapshot: Invalid change tracker error code.
2023-02-28T01:24:11Z INFO: Task to create snapshot completed, errors = true.
2023-02-28T01:24:11Z ERROR: Unable to create non-quiesced snapshot after a retry attempt: An error occurred while taking a snapshot: Invalid change tracker error code.
2023-02-28T01:24:11Z INFO: Disconnected from session on vCenter 'vCenter.local'.

Cause

A manual attempt to take a snapshot of the VM is failing within vCenter. 

Resolution

Workaround:

  1. vMotion the VM to another ESXi host.
  2. Run the manual snapshot again.
  3. Once a manual snapshot succeeds, the VM backup on the vProxy progresses
Contact VMware Support if a manual snapshot fails or if snapshot failures are persistent.

Overview of virtual machine snapshots in vSphere (1015180): https://kb.vmware.com/s/article/1015180 This hyperlink is taking you to a website outside of Dell Technologies.

Additional Information

Επηρεαζόμενα προϊόντα

NetWorker

Προϊόντα

NetWorker Family, NetWorker Series
Ιδιότητες άρθρου
Article Number: 000210940
Article Type: Solution
Τελευταία τροποποίηση: 16 Αυγ 2026
Version:  6
Βρείτε απαντήσεις στις ερωτήσεις σας από άλλους χρήστες της Dell
Υπηρεσίες υποστήριξης
Ελέγξτε αν η συσκευή σας καλύπτεται από τις Υπηρεσίες υποστήριξης.