VxRail: Kaynak Sanal Makineden Veri Dışa Aktarırken VMware vCenter Server Yükseltilemedi
Summary: VxRail VCenter yükseltmesi sırasında, kaynak vCenter sunucusundan hedef vCenter sunucusuna veri aktarılırken başarısız oluyor. Günlükten, "VMware Analytics Service verilerini dışa aktarmak" için çok zaman harcandığını gösteriyor. ...
Αυτό το άρθρο ισχύει για
Αυτό το άρθρο δεν ισχύει για
Αυτό το άρθρο δεν συνδέεται με κάποιο συγκεκριμένο προϊόν.
Δεν προσδιορίζονται όλες οι εκδόσεις προϊόντων σε αυτό το άρθρο.
Symptoms
VxRail'den
lcm-web.log:
2025-08-31T10:27:25.367Z <4304e36e4934ff08fc8120c70e58301b> lcm [WARN] <183> VirtualApplianceUpgradeService.java runUpgrade() (1158): LCM Exception occurred during upgrade for virtual appliance 0 - {}
com.vce.lcm.exception.LCMException: Failed to upgrade the VMware vCenter Server: Failed to export data from source VM VCENTER01.
at com.vce.lcm.api.LCMServiceImpl.handleUpgradeException(LCMServiceImpl.java:2129)
at com.vce.lcm.api.LCMServiceImpl.performUpgrade(LCMServiceImpl.java:509)
at com.emc.mystic.manager.upgrade.service.VirtualApplianceUpgradeService.runUpgrade(VirtualApplianceUpgradeService.java:1134)
at com.emc.mystic.manager.upgrade.service.PureUpgradeRestServiceImpl.lambda$retryVirtualApplianceUpgrade$0(PureUpgradeRestServiceImpl.java:129)
at java.base/java.util.concurrent.Executors$RunnableAdapter.call(Executors.java:515)
at java.base/java.util.concurrent.FutureTask.run(FutureTask.java:264)
at java.base/java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExecutor.java:1128)
at java.base/java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:628)
at java.base/java.lang.Thread.run(Thread.java:829)
Caused by: com.vce.lcm.exception.LCMInternalException: Failed to upgrade the VMware vCenter Server: Failed to export data from source VM VCENTER01.
at com.vce.lcm.core.upgrade.ComponentUpgradeService.performComponentUpgrade(ComponentUpgradeService.java:339)
at com.vce.lcm.api.LCMServiceImpl.performComponentUpgrade(LCMServiceImpl.java:2439)
at com.vce.lcm.api.LCMServiceImpl.performCompositeUpgrade(LCMServiceImpl.java:1845)
at com.vce.lcm.api.LCMServiceImpl.performUpgrade(LCMServiceImpl.java:507)
... 7 common frames omitted İtibaren /var/log/vmware/upgrade/export.json Yeni geliştirilen vCenter sunucusunun günlüğü, yükseltmenin başarısız olduğu durumlardaExporting VMware Analytics Service data..." ile TIME_OUT Error:
{
"progress": 37,
"progress_message": {
"id": "ur.upgrade.script.export.progress.text",
"translatable": "Exporting %(0)s data...",
"args": [
"VMware Analytics Service"
],
"localized": "Exporting VMware Analytics Service data..."
},
"status": "error",
"info": [],
"warning": [],
"question": null,
"error": {
"detail": [
{
"id": "ur.upgrade.execution.timedout.text",
"translatable": "Upgrade phase timed out. The time planned for the upgrade phase was %(0)s minutes. The upgrade phase has already been running for %(1)s minutes.",
"args": [
60,
60
],
"localized": "Upgrade phase timed out. The time planned for the upgrade phase was 60 minutes. The upgrade phase has already been running for 60 minutes."
}
],
"componentKey": "upgrade_framework",
"problemId": null,
"resolution": {
"id": "ur.upgrade.execution.timedout.resolution",
"translatable": "To extend the default timeout, set environment variable %(0)s for export upgrade phase, %(1)s for import upgrade phase, and %(2)s for import historical data phase. The timeout is in minutes.",
"args": [
"UPGRADE_EXPORT_TIMEOUT",
"UPGRADE_IMPORT_TIMEOUT",
"UPGRADE_POST_IMPORT_TIMEOUT"
],
"localized": "To extend the default timeout, set environment variable UPGRADE_EXPORT_TIMEOUT for export upgrade phase, UPGRADE_IMPORT_TIMEOUT for import upgrade phase, and UPGRADE_POST_IMPORT_TIMEOUT for import historical data phase. The timeout is in minutes."
}
},Cause
Bu sorun, anında iletme telemetri işleminin benzersiz kimliklere sahip aşırı sayıda istek göndermesi ve bu da içinde çok sayıda dosya oluşturulmasına neden olması nedeniyle oluşur./var/log/vmware/analytics/prod" dizinini seçin. Bazen bu, 185.000 ila 375.000 dosyanın birikmesine yol açmıştır.
Resolution
Bkz. KB https://knowledge.broadcom.com/external/article/322053/vcenter-server-upgrade-from-70-to-80-fai.html (Harici Bağlantı)
- SSH kullanarak kaynak vCenter sunucusuna bağlanma
- Gönderim telemetri işlemi nedeniyle vCenter sunucusunda oluşturulan dosya sayısını kontrol etmek için aşağıdaki komutu çalıştırın:
ls /var/log/vmware/analytics/prod | wc -l - Şunu indirin :
cleaning_vddk_script.shKomut dosyasını bu makalenin Ekler bölümünden indirebilirsiniz. - Komut dosyasını vCenter'a yükleyin ve şu komutla "çalıştır" izinleri atayın:
chmod +x cleaning_vddk_script.sh - Şu komut dosyasını çalıştırın:
./cleaning_vddk_script.sh - VxRail eklentisinden yükseltmeyi yeniden başlatın.
Επηρεαζόμενα προϊόντα
VxRail, VxRail Appliance SeriesΙδιότητες άρθρου
Article Number: 000372265
Article Type: Solution
Τελευταία τροποποίηση: 31 Οκτ 2025
Version: 3
Βρείτε απαντήσεις στις ερωτήσεις σας από άλλους χρήστες της Dell