PowerVault ME4-ME5: ePSA error code 2000-0151 reported by PowerEdge diagnostics with SAS attached array

Summary: Dell Enhanced Pre-Boot System Assessment (ePSA) or Dell Pre-Boot System Assessment (PSA) Diagnostics that are run against a SAS attached PowerVault ME series array reports a false positive error. Use PowerVault Manager or CLI to assess the PowerVault ME series SAN health. ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Instructions

ePSA diagnostics may return error code: 2000-0151 when run against a PowerVault ME series array that is attached to a Dell PowerEdge server using a SAS cable to a Dell 12 Gb SAS HBA or Dell HBA355e.  

ePSA diagnostic returning error code 2000-0151

This alert can be ignored for external SAS attached SAN, disk drive status within the PowerVault ME series can be determined using PowerVault Manager and PowerVault ME event logs. See the PowerVault ME Storage System Administrator’s Guide, the documentation for your model is available on dell.com/support.

This is resolved in ePSA application release build 4301.77 and later.  The updated package can found on dell.com/support under the Drivers & Downloads section for some PowerEdge models. Dell 64-Bit uEFI Diagnostics is found under the Diagnostics category.

 
 

Affected Products

Rack Servers, Tower Servers, Dell EMC PowerVault ME4012, Dell EMC PowerVault ME4024, Dell EMC PowerVault ME4084, PowerVault ME5012, PowerVault ME5024, PowerVault ME5084
Article Properties
Article Number: 000202362
Article Type: How To
Last Modified: 05 Apr 2023
Version:  4