PowerFlex : How To Change LIA Token After Installation

Summary: When LIA has been installed with an incorrect token, or the customer want to change the token without reinstall the LIA agent.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

How to configure the LIA password manually after the ScaleIO Cluster is deployed.
Is it possible to manually set/change the LIA admin password on a per node basis after the cluster has been deployed?

Cause

 

Resolution

  1. Go to the LIA conf file and open it.
    • Linux location: "/opt/emc/scaleio/lia/cfg/conf.txt"
    • Windows location: "C:\Program Files\EMC\scaleio\lia\cfg\conf.txt"
  2. "lia_token" value is the hashed value of the token provided on installation, replace it with the token you want to use. Below is an example
    Before change:

    lia_token=3d32aa40caffcce4ba40811bccd97dbe3531fb0797119f59ec1b633cb3a5a85a
    After change:
    lia_token=Scaleio123!
    
  3. Restart the LIA agent service
    • On Linux: Run the next command

      pkill lia
      
    • On Windows: Open cmd and run the next command

      net stop lia_service && net start lia_service
      
  4. LIA will rehash the token and apply the new token.

Affected Products

PowerFlex appliance connectivity