Validating Physical NICs are Symmetric Fails When Creating Network ATC NetIntent When Using Intel X710 Network Adapters

Summary: During the Network ATC NetIntent validation process for Intel X710 Network Adapters, an error arises due to inconsistencies identified within the NICs' description.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Instructions

Example of the difference in network adapter descriptions which causes the validation error.
 
Example of the different Intel NIC network adapter descriptions
Figure 1: Example of the different Intel NIC network adapter descriptions 
 
Example two of the different Intel NIC network adapter descriptions
Figure 2: Example two of the different Intel NIC network adapter descriptions 

Example of different driver versions on network adapters which causes the difference in network adapter descriptions.
 
Example of Intel Drivers versions on the network adapters which cause the issue
Figure 3: Example of Intel Drivers versions on the network adapters which cause the issue

Resolution:
The recommendation is to install Intel NIC Family version 21.5.0 drivers which are designed for Microsoft Azure Stack, version 22H2, with package ID NVPY7. You can access the driver package using the provided link. Once installed, the driver version should show as version 1.16.206.0 on all Intel X710 network adapters. After installing the 21.5.0 driver which will align the network adapter descriptions you can then update to a later version driver. 

Known Issues::
After Downgrade the Driver may still show 1.16.208 even though the installer says it is .206. If so you must either uninstall the driver or re-upgrade to .208 and then attempt to downgrade again. 

Affected Products

Dell EMC Microsoft Storage Spaces Direct Ready Nodes, Storage Spaces Direct R440 Ready Node, Storage Spaces Direct R640 Ready Node, Storage Spaces Direct R740xd Ready Node, Storage Spaces Direct R740xd2 Ready node

Attachments

Dell article 217925 Validating Physical NICs are Symmetric Fails When Creating Network ATC NetIntent When Using Intel X710 Network Adapters_pkb_en_US_1.docx

Article Properties
Article Number: 000217925
Article Type: How To
Last Modified: 05 Sept 2025
Version:  6
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.