PowerProtect: Sikkerhetskopiering mislykkes på grunn av problem med nettverkskonfigurasjon

Summary: Agentskriving til datadomene kan mislykkes på grunn av flere mulige problemer med nettverkskonfigurasjonen.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Denne typen feil rapporteres i agentlogger:
 
ddbmsqlsv PowerProtect Data Manager critical Unable to write data into multiple buffers for save-set ID '1717311875': Invalid argument (errno=22) 
critical XBSA Internal system error. 
critical Write on "EMC#a0c5da26-9391-4133-b943-55f007ab894c" failed: 995(The I/O operation has been aborted because of either a thread exit or an application request.)
critical (Error: 3202) 
Unable to obtain file system information for backup ID '1717311875': 'Accessing file statistics failed [5040] 
ddp_fstat() failed, Err: 5040-connection no longer valid

Cause

Flere mulige årsaker er:
Data Domain-grensesnittet bruker DHCP.
Data Domain-grensesnittet er konfigurert for dynamisk ruting.
Data Domain Storage-enhetskvoten overskrides.
Data Domain-IP er ikke unik i DNS.

Resolution

Angi Data Domain-grensesnitt som brukes av PowerProtect Data Manager til å bruke statiske IP-adresser.
Konfigurer statiske ruter på Data Domain for kommunikasjon med PowerProtect Data Manager-server, agenter og proxy-virtuelle maskiner.
Kontroller og juster lagringsenhetskvoter.
Kontroller og juster ledig plass på Data Domain.
Kontroller og rett opp Data Domain fra PowerProtect Data Manager-servere, agenter og proxy-virtuelle maskiner. 