與安全分數結果相關聯的 Windows 事件是什麼

Summary: 本文提供 Dell 受信任裝置完成安全性評估後的 Windows 事件記錄範例。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Instructions

受影響的產品:

  • Dell Trusted Device

受影響的平台:

  • OptiPlex
  • Latitude
  • Precision 工作站
  • XPS

目錄:

與安全性分數結果相關聯的 Windows 事件

Windows 事件詳細資料

以下章節顯示一些相關的 Windows 事件記錄範例:

  • 安全性分數
  • BIOS 驗證
  • 攻擊的指標
  • ME 驗證

回到頁首

安全性分數

每次刷新安全分數評估時,安全分數外掛程式都會生成一個事件。寫入 Dell 應用程式事件記錄的安全性分數評估事件具有名為 「受信任裝置 |安全性評估

大事記

以下是為安全分數評估生成的事件示例。

結果:通過 (範例)

Event ID: 13
Level: Informational
Dell Trusted Device has completed a security scan of the system with service tag xxxxxxx at 9/28/2020 2:56:08 PM.
Result: PASSED

Score: 100

Risk Areas Scanned:
(Passed: 7, Warning: 0, Fail: 0)
- Antivirus solution detected and enabled: PASS
- BIOS Admin Password set: PASS
- BIOS Verification: PASS
- Disk Encryption: PASS
- Firewall solution detected and enabled: PASS
- Indicators of Attack detected: PASS
- TPM enabled: PASS

結果:已通過,但有警告(範例)

Event ID: 14
Level: Warning
Dell Trusted Device has completed a security scan of the system with service tag xxxxxxx at 9/28/2020 2:56:08 PM.
Result: PASSED, with warnings

Score: 100

Risk Areas Scanned:
(Passed: 6, Warning: 1, Fail: 0)
- Antivirus solution detected and enabled: PASS
- BIOS Admin Password set: PASS
- BIOS Verification: PASS
- Disk Encryption: WARNING
- Firewall solution detected and enabled: PASS
- Indicators of Attack detected: PASS
- TPM enabled: PASS

結果:失敗(示例)。

Event ID: 15
Level: Error
Dell Trusted Device has completed a security scan of the system with service tag xxxxxxx at 9/28/2020 5:05:22 PM.
Result: FAILED
 
Score: 71
 
Risk Areas Scanned:
(Passed: 4, Warning: 1, Fail: 2)
- Antivirus solution detected and enabled: PASS
- BIOS Admin Password set: PASS
- BIOS Verification: PASS
- Disk Encryption: WARNING
- Firewall solution detected and enabled: PASS
- Indicators of Attack detected: FAIL
- TPM enabled: FAIL

回到頁首

BIOS 驗證

如果 BIOS 驗證完成並成功,Dell 應用程式事件記錄中會寫入說明結果的資訊層級項目。如果 BIOS 驗證處理因任何原因無法完成,則會在 Windows 系統事件記錄中寫入一個錯誤層級 (或警告層級) 項目,說明故障。寫入 Windows 系統事件記錄的項目有名為 Dell Trusted Device |Intel BIOS 驗證。

大事記

事件 ID 4 指示以下錯誤類型:

驗證失敗

BIOS Verification failed and have a Fail evaluation.
Event ID: 4
Level: Error

BIOS Verification : 1 (Failed Result)
[Displays the complete Json Payload.]

偵測篡改:

BIOS Verification failed and have a tampering detected error
Event ID: 4
Level: Error
BIOS Verification : 2 (Tampered Result)
[Displays the complete Json Payload.]

事件 ID 2 表示以下錯誤類型:

驅動程式錯誤

BIOS Verification failed and have a driver error.
Event ID: 2
Level: Error
BIOS Verification : 8 (Driver Error).
See log file for more information

網路連線錯誤

BIOS Verification failed and have a network connection error
Event ID: 2
Level: Error
BIOS Verification : 13 (Network Connectivity Error)
See log file for more information

不支援的平台

BIOS Verification failed and have a platform unsupported error
Event ID: 2
Level: Error
BIOS Verification : 11 (Platform Not Currently Supported)
See log file for more information

未知錯誤

BIOS Verification failed and have an unknown error
Event ID: 2
Level: Error

BIOS Verification : 3 (Unknown Error).
See log file for more information

內部伺服器錯誤

BIOS Verification failed and have an internal error
Event ID: 2
Level: Error
BIOS Verification : 6 (Internal Error).
See log file for more information

無效的 BIOS 資料錯誤

BIOS Verification failed and have an invalid bios data error
Event ID: 2
Level: Error
BIOS Verification : 9 (Invalid BIOS Data Error).
See log file for more information

回到頁首

攻擊的指標

攻擊指標 (IoA) 附掛程式產生的事件旨在回報 IoA 威脅鏈中的狀態變更。

  • 寫入 Windows 系統事件記錄的 IoA 事件有一個名為 Dell Trusted Device 的來源 |BIOS 事件與 IoA
  • 寫入 Dell 應用程式事件記錄的 IoA 事件有一個名為 「受信任裝置 |BIOS 事件與 IoA
大事記

IoA 附掛程式會產生下列事件。這些內容可能略有不同,例如 <<攻擊類型>> 和相關 <<屬性更改>>,具體取決於所涉及的威脅鏈。寫入事件時,變數內容將替換為實際內容。

目前事件 ID 定義與威脅的目前狀態相關聯:

  • 10 表示未符合鏈結準則。
  • 11 表示鏈標準已滿足部分攻擊的級別。
  • 12 表示已完全滿足鏈結標準。

偵測到部分攻擊

When a partial attack is detected, the following event is written:
Event ID: 11
Level: Warning
A partial Indicator of Attack was detected (Category: <<Attack Type>>) based on the following events:
<<Relevant Attribute Changes>>

部分攻擊升級為完整攻擊:

When a partial attack escalates to a full attack, the following event is written:
Event ID: 12
Level: Error
A partial Indicator of Attack has escalated (Category: <<Attack Type>>) based on the following events:
<<Relevant Attribute Changes>>

清除部分攻擊

When a partial attack is cleared, the following event is written:
Event ID: 10
Level: Information
A partial Indicator of Attack has been cleared (Category: <<Attack Type>>).

全面攻擊

When a threat chain goes from clear to detecting a full attack, the following event is written:
Event ID: 12
Level: Error
An Indicator of Attack was detected (Category: <<Attack Type>>) based on the following events:
<<Relevant Attribute Changes>>

完全攻擊降低為部分攻擊

When a full attack is reduced to a partial attack, the following event is written:
Event ID: 11
Level: Warning
An Indicator of Attack has been reduced (Category: <<Attack Type>>) based on the following events:
<<Relevant Attribute Changes>>

已清除完全攻擊

When a full attack is cleared, the following event is written:
Event ID: 10
Level: Information
An Indicator of Attack has been cleared (Category: <<Attack Type>>).

回到頁首

ME 驗證

ME 驗證處理 ME 驗證程序。如果 ME Verification 完成並成功,Dell 應用程式事件記錄中會寫入說明結果的資訊層級項目。如果 ME Verification 處理因任何原因無法完成,則會將錯誤層級 (或警告層級) 項目寫入 Windows 系統事件記錄和說明故障的 Dell 應用程式事件記錄:

  • 寫入 Windows 系統事件記錄的項目有名為 Dell Trusted Device |Intel ME 驗證
  • 寫入 Dell 應用程式事件記錄的項目有一個名為 「受信任裝置 |Intel ME 驗證
大事記

ME 驗證外掛程式會產生下列事件:

目前事件 ID 定義與紀錄記錄等級相關聯:

  • 18 表示其為資訊輸入類型。
  • 19 表示它是警告條目類型。
  • 20 表示它是錯誤條目類型。

驗證成功

ME Verification succeeded and have a Pass evaluation
Event ID: 18
Level: Information
Dell Trusted Device has completed an Intel ME Verification scan of the system with service tag G1CCLQ2 at 4/28/2021 2:56:08 PM.
Result: PASSED

驗證失敗

ME Verification failed and have a Fail evaluation
Event ID: 20
Level: Error
Dell Trusted Device has completed an Intel ME Verification scan of the system with service tag G1CCLQ2 at 4/28/2021 2:56:08 PM.
Result: FAILED

驅動程式錯誤

ME Verification failed and have a driver error
Event ID: 20
Level: Error
Dell Trusted Device has completed an Intel ME Verification scan of the system with service tag G1CCLQ2 at 4/28/2021 2:56:08 PM.
Result:Error. A driver error has occurred

網路連線錯誤

ME Verification failed and have a network connection error
Event ID: 20
Level: Error
Dell Trusted Device has completed an Intel ME Verification scan of the system with service tag G1CCLQ2 at 4/28/2021 2:56:08 PM.
Result:Error. A network connection error occurred

不支援的平台

ME Verification failed and have a platform unsupported error
Event ID: 20
Level: Error
Dell Trusted Device has completed an Intel ME Verification scan of the system with service tag G1CCLQ2 at 4/28/2021 2:56:08 PM.
Result:Error. Platform not currently supported

伺服器內部錯誤

Event ID: 20
Level: Error
Dell Trusted Device has completed an Intel ME Verification scan of the system with service tag G1CCLQ2 at 4/28/2021 2:56:08 PM.
Result:Error. An internal error occurred within the server

偵測篡改:

ME Verification failed and have a tampering detected error
Event ID: 20
Level: Error
Dell Trusted Device has completed an Intel ME Verification scan of the system with service tag G1CCLQ2 at 4/28/2021 2:56:08 PM.
Result:Error. Tampering has been detected

未知錯誤

ME Verification failed and have an unknown error
Event ID: 20
Level: Error
Dell Trusted Device has completed an Intel ME Verification scan of the system with service tag G1CCLQ2 at 4/28/2021 2:56:08 PM.
Result:Error. An unknown error has occurred

無效的參數

ME Verification issues a warning about invalid parameter
Event ID: 19
Level: Warning
Dell Trusted Device has completed an Intel ME Verification scan of the system with service tag G1CCLQ2 at 4/28/2021 2:56:08 PM.
Result:Warning. The parameter is invalid

回到頁首

在 IoAs 中使用的 BIOS 屬性

注意:
  • 螢幕擷取畫面為範例,可能無法直接反映特定平台的確切 BIOS 屬性。
  • 此圖表是動態的,因為創建了其他 IoA。
伊奧阿斯 BIOS 螢幕擷取畫面
安全開機 啟用安全開機
Attempt LegacyBoot 進階開機選項
開機清單 開機清單選項
UEFIBootPathSecurity UEFI 開機路徑安全性
AutoOSThresholdRecovery 自動作業系統復原臨界值
允許生物降級 BIOS 降級
CapsuleFirmwareUpdate UEFI Capsule 韌體更新
BIOS 自動復原 BIOS 復原
TPMActivation TPM 2.0 安全性
TPM TPM 開啟
TPMClear 清除
TPMPpiClearOverride 清除命令 TPM 略過
自動開啟 自動開機時間
WakeOnLAN 網路/無線網路喚醒
RemoteWipeInternalDrives 資料抹除
USBWake USB 喚醒支援
喚醒擴充基座 電力管理
TPMRemoteActivation TBD
AdminPwMinLen 密碼組態
PwdMinLen TBD
StrongPassword 強式密碼
AdminSetupLockout 管理員設定鎖定
BIOSAdminPwd TBD
ClearBIOSLog TBD
ClearPowerLog TBD
清除散熱記錄 TBD
清除機箱入侵警告 機箱入侵偵測
清除 DellRMTLog TBD
機箱入侵偵測報告 清除侵入警告
機箱入侵偵測 N/A
麥克風 音訊

回到頁首


如要聯絡支援部門,請參閱 Dell Data Security 國際支援電話號碼
請前往 TechDirect,以線上產生技術支援要求。
如需更多深入見解與資源,請加入 Dell 安全性社群論壇

Additional Information

Affected Products

OptiPlex, XPS, Latitude, XPS, XPS Tablets, Fixed Workstations, Mobile Workstations, Dell Trusted Device
Article Properties
Article Number: 000233967
Article Type: How To
Last Modified: 09 Oct 2024
Version:  2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.