Isilon:如何检查电源是否发生故障?

Summary: 如何检查电源是否发生故障

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Instructions

要检查电源是否确实发生故障:
  1. 在群集中的任意节点上打开 SSH 连接,然后使用“root”帐户登录。
  2. 运行以下命令,

检查一个节点上的电源状态:

# isi_hw_status | grep -i -A2 "Power Supplies"

Power Supplies OK
Power Supply 1 good
Power Supply 2 good
检查所有节点上的电源状态
 
# isi_for_array -s isi_hw_status | grep -i -A2 "Power Supplies"

RTPIsilon02-1: Power Supplies OK
RTPIsilon02-1: Power Supply 1 good
RTPIsilon02-1: Power Supply 2 good
--
RTPIsilon02-2: Power Supplies OK
RTPIsilon02-2: Power Supply 1 good
RTPIsilon02-2: Power Supply 2 good


从上面的输出中,我们可以发现所有电源都正常。因此,无需执行任何操作。

如果所有电源都正常,则清除虚假警报并监视群集 24 小时

如需仅清除特定电源警报
使用以下命令获取组 ID

# isi event groups list

ID   Started     Ended       Causes Short                  Lnn  Events  Severity
-----------------------------------------------------------------------------------
3074 01/01 00:25 01/01 00:25 POWER Supply Failed           4    1      Critical

 

# isi event groups modify --resolved=yes --ignore=yes --id=<上述命令中的组 ID>

Eg : isi event groups modify --resolved=yes --ignore=yes --id=3074



如需清除整个群集上的所有旧警报

对于 OneFS 7.x.x.x

# isi events cancel all
# isi events quiet all




对于 OneFS 8.x.x.x

# isi event bulk --ignore=true
# isi event bulk --resolved=true

 

 

Additional Information

如果您在输出中发现电源发生故障,请联系 Isilon 支持进行更换。

请观看以下视频,此视频也发布在 YouTube 上:

Affected Products

Isilon, PowerScale OneFS