Isilon: How to check if a Power Supply has failed?
Summary: How to check if a Power Supply has failed
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Instructions
To check if a Power Supply has genuinely failed:
- Open an SSH connection on any node in the cluster and log on using the "root" account.
- Run the following command,
To check the status of Power supply on one Node:
# isi_hw_status | grep -i -A2 "Power Supplies" Power Supplies OK Power Supply 1 good Power Supply 2 good
To check the status of Power supply on all the Nodes
From the above output we notice that all the Power supplies are OK. Hence no action needed.
# isi_for_array -s isi_hw_status | grep -i -A2 "Power Supplies" RTPIsilon02-1: Power Supplies OK RTPIsilon02-1: Power Supply 1 good RTPIsilon02-1: Power Supply 2 good -- RTPIsilon02-2: Power Supplies OK RTPIsilon02-2: Power Supply 1 good RTPIsilon02-2: Power Supply 2 good
From the above output we notice that all the Power supplies are OK. Hence no action needed.
If all the Power Supplies are good. Clear the false alerts and monitor the cluster for 24 hours
To clear only the specific Power Supply alert
Get the group id using the following command
# isi event groups list ID Started Ended Causes Short Lnn Events Severity ----------------------------------------------------------------------------------- 3074 01/01 00:25 01/01 00:25 POWER Supply Failed 4 1 Critical
# isi event groups modify --resolved=yes --ignore=yes --id=<Group ID from above command >
Eg : isi event groups modify --resolved=yes --ignore=yes --id=3074
To clear all old alerts on Entire cluster
For OneFS 7.x.x.x
# isi events cancel all # isi events quiet all
For OneFS 8.x.x.x
# isi event bulk --ignore=true # isi event bulk --resolved=true
Additional Information
If you notice a Power Supply as failed in the output, contact Isilon Support for a replacement.
Please watch this video:
Please watch this video:
Affected Products
Isilon, PowerScale OneFSArticle Properties
Article Number: 000020717
Article Type: How To
Last Modified: 17 Mar 2023
Version: 4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.