ECS: xDoctor: RAP015: Tuulettimen vika

Summary: Tuuletin ilmoittaa solmun vikatilasta.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Solmun tuuletin on lakannut ilmoittamasta, että se on toimintakunnossa.
Tuuletin on ilmoittanut olevansa vikatilassa ja voi aiheuttaa solmun ylikuumenemisen, jos siihen ei puututa.  
----------------------
CRITICAL - Fan Failure
----------------------
Node      = 169.254.1.3
Extra     = {'node': '169.254.1.3', 'item': 'Fan1', 'status': 'CRIT', 'fan': 'System Board', 'info': '0 RPM, below critical threshold'}
RAP       = RAP015
Solution  = KB 470284
Timestamp = 2023-08-22_102927
PSNT      = CKMxxxxxxxxxxx @ 4.8-92.0
----------------------
CRITICAL - Fan Failure
----------------------
Node      = 169.254.1.3
Extra     = {'node': '169.254.1.3', 'item': 'Fan Redundancy', 'status': 'FAIL', 'fan': 'System Board', 'info': 'not redundant, redundancy lost'}
RAP       = RAP015
Solution  = KB 470284
Timestamp = 2023-08-22_102927
PSNT      = CKMxxxxxxxxxxx @ 4.8-92.0

Cause

Sähköviasta tai iästä johtuva liikkuvan komponentin vika.

Resolution

Yhdistä kyseiseen solmuun ja tarkista ongelma:
Tarkista ilmoitetun solmun tuulettimen tila cs_hal:llä.
 

Issue-komento: # cs_hal anturien tuuletin
 
Esimerkki terveestä tuulettimesta:
admin@node3:~> cs_hal sensors fan
Entity            Type                Label             Status  Info
-----             -----               -----             -----   -----
System Board      Fan                 Fan1              OK      12600 RPM
System Board      Fan                 Fan2              OK      12600 RPM
System Board      Fan                 Fan3              OK      16920 RPM
System Board      Fan                 Fan4              OK      16920 RPM
System Board      Fan                 Fan5              OK      17040 RPM
System Board      Fan                 Fan6              OK      17040 RPM
System Board      Fan                 Fan Redundancy    OK      fully redundant;

Alla näkyy muiden tuulettimien nopeus, mikä lisää ilmavirtausta, joka pitää solmun viileänä, kunnes tuuletin on vaihdettu.

Esimerkki epäonnistuneesta tuulettimesta:

admin@node3:~> cs_hal sensors fan
Entity            Type                Label             Status  Info
-----             -----               -----             -----   -----
System Board      Fan                 Fan1              CRIT    0 RPM; below critical threshold
System Board      Fan                 Fan2              OK      13440 RPM
System Board      Fan                 Fan3              OK      20640 RPM
System Board      Fan                 Fan4              OK      20880 RPM
System Board      Fan                 Fan5              OK      20880 RPM
System Board      Fan                 Fan6              OK      20640 RPM
System Board      Fan                 Fan Redundancy    FAIL    not redundant; redundancy lost;
Issue-komento: # sudo ipmitool -H <BMC_IP> -U root -P passwd -I lanplus sdr tyyppi "Fan"
admin@node3:~> sudo ipmitool -H 192.168.219.103 -U root -P passwd -I lanplus sdr type "Fan"
Fan1             | 38h | lcr |  7.1 | 0 RPM     
Fan2             | 39h | ok  |  7.1 | 13440 RPM
Fan3             | 3Ah | ok  |  7.1 | 20640 RPM
Fan4             | 3Bh | ok  |  7.1 | 20880 RPM
Fan5             | 3Ch | ok  |  7.1 | 20880 RPM
Fan6             | 3Dh | ok  |  7.1 | 20640 RPM
Fan Redundancy   | 78h | ok  |  7.1 | Redundancy Lost
Issue-komento: # sudo -i racadm getsensorinfo
(cutting the complete output.)
admin@node3:~> sudo -i racadm getsensorinfo

Sensor Type : FAN
<Sensor Name>                   <Status>    <Reading>   <lc>        <uc>        <PWM %>     <Type>
System Board Fan1               Failed      0RPM        480RPM      NA          NA          High Performance 
System Board Fan2               Ok          13440RPM    480RPM      NA          65%         High Performance
System Board Fan3               Ok          20640RPM    480RPM      NA          100%        High Performance
System Board Fan4               Ok          20640RPM    480RPM      NA          100%        High Performance
System Board Fan5               Ok          20880RPM    480RPM      NA          100%        High Performance
System Board Fan6               Ok          20640RPM    480RPM      NA          100%        High Performance


<Sensor Name>                   <Status>                 <Type>
System Board PS Redundancy      Full Redundant           PSU
System Board Fan Redundancy     Redundancy Lost          Fan 

Jos jonkin tuulettimen tila ei ole kunnossa CRIT-raportoinnin mukaan, tuuletin on viallinen ja se on vaihdettava. Jos sinulla ei ole palvelupyyntöä tälle ongelmalle, avaa pyyntö ECS-tuelle ja viittaa tähän tietämyskannan artikkeliin.