Connectrix MDS:MDS 9706 或 9710 的升級失敗,並出現錯誤「bootflash busy;安裝 bootflash 時發生故障」
Summary: 從 NX-OS 6.2.19 升級至 8.1.1 後,使用者無法再看到「bootflash://sup-standby」。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
從 NX-OS 6.2.19 升級至 8.1.1。
升級後,使用者將無法再看到「bootflash://sup-standby」。
如下所示:
正常運作的交換器會顯示下列內容:
問題的其他徵兆如下:
升級後,使用者將無法再看到「bootflash://sup-standby」。
如下所示:
MDS1# dir bootflash: bootflash:/// bootflash://module-5/ bootflash://sup-1/ bootflash://sup-active/ bootflash://sup-local/
MDS2# dir bootflash: bootflash:/// bootflash://module-6/ bootflash://sup-2/ bootflash://sup-local/ bootflash://sup-standby/ bootflash://module-5/ bootflash://sup-1/ bootflash://sup-active/ bootflash://sup-remote/ <---------------
- ISSU/D 故障並顯示下列錯誤訊息:
Pre-upgrade check failed. Return code 0x4093007E (Issue cannot be done, bootflash is busy). 'segmentation fault' error messages when issuing `sys health check bootflash`: switch# sys health check bootflash Unmount successful... Checking any file system errors...Please be patient... /isanboot/sbin/format-bootflash: line 75: 7598 Segmentation fault $SUDO $E2FSCK -n -v $@ > /dev/null 2> /dev/null done. Remounting bootflash .../isanboot/sbin/format-bootflash: line 62: 7600 Segmentation fault $SUDO /bin/mount $MNT_BOOTFLASH_DIR Failed to mount bootflash bootflash on the affected supervisor is not available switch# dir no such file or directory (invalid server) Logging log outputs: %BOOTVAR-2-AUTOCOPY_STANDBY_MOUNT_FAILED: Autocopy failed to access standby file system via NFS mount.Please, copy the boot images manually to standby bootflash. %SYSMGR-2-LAST_CORE_BASIC_TRACE: : PID 6688 with message non-sysmgr(non-sysmgr) crashed, core will be saved . Core file also generated: `show cores` Module Instance Process-name PID Date(Year-Month-Day Time) ------ -------- --------------- -------- ------------------------- 5 1 non-sysmgr 6688 2017-10-08 07:29:07
Cause
此問題在 Cisco CSCvb93701 中識別為以下專案:
根據已記錄的 Cisco 問題:
ISSU/D fails on MDS 9706/9710 with 'bootflash busy' error; seg fault while mounting bootflash CSCvb93701 (see also CSCvf99665)
The system is only affected if it was previously running one of the following NX-OS releases: 6.2(17) - 6.2(19) 7.3(0)D1(1) - 7.3(1)D1(1) 7.3(0)DY(1) - 7.3(1)DY(1) This issue does not apply to any other NX-OS releases on MDS 9706 and 9710 platforms. It does not occur on the MDS 9718 platform.
Resolution
解決 方案:
管理介面上的 IPv6 無效子網會導致此問題。
請聯絡 Dell 技術支援以取得復原協助。
管理介面上的 IPv6 無效子網會導致此問題。
switch13# show interface mgmt0
mgmt0 is up
Hardware is GigabitEthernet
Address is 2cab.ebfd.4386
Internet address(es):
10.8.96.223/23
::148.125.166.255/0 <--- "0" indicates an invalid subnet
fe80::2eab:ebff:fefd:4386/64
請聯絡 Dell 技術支援以取得復原協助。
Affected Products
Connectrix MDS-9710Products
Connectrix MDS-9706, Connectrix MDS-9710Article Properties
Article Number: 000052402
Article Type: Solution
Last Modified: 21 Sept 2023
Version: 4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.