Connectrix MDS 系列:由于温度传感器驱动程序错误,模块 X 报告了警告
Summary: Connectrix MDS 系列:由于设备 49 中的温度传感器驱动程序错误(设备错误 0xc310020b),模块 X 报告警告
Symptoms
其中一个交换机模块上的多个传感器断开,但模块正常运行。`show module`Mod Ports Module-Type Model Status--- ----- ----------------------------------- ------------------ ----------x 48 1/2/4/8 Gbps FC Module DS-X9248-96K9 okshow logging log:%MODULE-4-MOD_WARNING: Module X reported warning due to Temperature sensor driver error in device 49 (device error 0xc310020b) ********* Exception info for module X ********exception information --- exception instance 1 ----Module Slot Number: XDevice Id : 49Device Name : Temperature-sensorDevice Errorcode : 0xc3103217Device ID : 49 (0x31)Device Instance : 03 (0x03)Dev Type (HW/SW) : 02 (0x02)ErrNum (devInfo) : 23 (0x17)System Errorcode : 0x40380022 TempSensor on this module failed (or inaccessible)Error Type : Minor errorPhyPortLayer :Port(s) Affected :DSAP : 39 (0x27)UUID : 24 (0x18)Time : Fri May 19 20:38:38 2017 (Ticks: 591F900E jiffies) Temperature:--------------------------------------------------------------------Module Sensor MajorThresh MinorThres CurTemp Status (Celsius) (Celsius) (Celsius) --------------------------------------------------------------------11 Outlet1 n/a n/a n/a Failure 11 Outlet2 n/a n/a n/a Failure 11 Intake1 n/a n/a n/a Failure
Cause
Resolution
- 重新加载受影响的模块。这会中断通过模块的流量。
- 如果重新加载模块后状态仍然存在,请更换模块。
如果问题仍然存在,请联系您的 Dell Technology 客户服务代表或 Dell Technology 客户支持中心寻求技术支持,并将交换机日志上传到服务请求中,以便支持人员可以检查并向您提供反馈。报价此解决方案 ID 000052605。