Dell Unity: SP-panik, når begge administrationskabler fjernes/indsættes for hurtigt i samme periode

Summary: SP Panik, når begge administrationskabler fjernes/indsættes for hurtigt i samme periode. (Kan rettes af brugeren)

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Unity SP kan nogle gange gå i panik, når kunder skifter administrationskabler for hurtigt.

 

Cause

Hvis MGMT-komponenter som ECOM kører på SPA, trækker vi kablet ud af SPA, komponenter ville være failover til SPB. Men før failover er fuldført, hvis SPB-kablet trækkes ud, og SPA-kablet er tilsluttet igen. Derefter kan dette problem blive udløst.

//spb/EMC/C4Core/logs/start_c4.log
Thu Jul 26 09:47:04 UTC 2018 carrier.sh: changing Connectivity state to 0
Thu Jul 26 09:48:05 UTC 2018 carrier.sh: changing Connectivity state to 1
Thu Jul 26 09:48:14 UTC 2018 peservice.sh: /EMC/fastvp is NOT  mounted, cannot start PEService.exe <========

Like start_c4.log above, after cable was pulled out from SPB at 2018-07-26 09:48:05 , some components were stopped while some not stopped at all, then cable was plugged in back.
Then non-stopped components never restarted, while those stopped components started to start like c4fastvpa. And the components which c4fastvpa depends on like c4loga and metricsluna never stopped in this process.
Ungraceful failover messed up the start-up sequence of components and may make SP panic.

 

Resolution

Denne mekanisme fungerer efter design. Kunden bør ikke skifte netværkskabel for hurtigt. Foreslå at vente 5 - 10 minutter før nogen ændring på et andet kabel.

 