Cisco MDS: Il comando "no shutdown" dell'interfaccia non viene visualizzato in running-config dopo ISSU 8.4(1) e 8.4(1a)

Summary: Cisco MDS: Il comando "no shutdown" dell'interfaccia non viene visualizzato in running-config dopo ISSU 8.4(1) e 8.4(1a)

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Aggiornato alla versione 8.4(1) o 8.4(1a)

Sintomo 1: Il comando "show running-config diff" mostra una differenza nel numero di righe tra la configurazione in esecuzione e quella di avvio. E indica le differenze di avvio nella configurazione del canale della porta:

show running-config diff
*** Startup-config
--- Running-config
***************
*** 1057,1072 ****
    ip address 10.210.0.13 255.255.255.0

  interface port-channel30
    switchport mode E
    switchport rate-mode dedicated
-   no shutdown
  interface port-channel200
    switchport mode F
    switchport rate-mode dedicated
-   no shutdown
  vsan database
    vsan 30 interface port-channel30
    vsan 10 interface port-channel200
    vsan 10 interface fc1/9
    vsan 10 interface fc1/10
--- 1057,1070 ----

Sintomo 2: il confronto diretto tra gli output show running config e show startup config mostra la differenza tra i due:

show running config

interface port-channel30
  switchport mode E
  switchport rate-mode dedicated

interface port-channel200
  switchport mode F
  switchport rate-mode dedicated

show startup config:

interface port-channel30
  switchport mode E
  switchport rate-mode dedicated
  no shutdown<-------------------------------not listed in running config

interface port-channel200
  switchport mode F
  switchport rate-mode dedicated
  no shutdown<--------------------------------------------not listed in running config
vsan database
  vsan 30 interface port-channel30
  vsan 10 interface port-channel200

Esempi aggiuntivi di differenze tra i sintomi:
Alla versione 8.3(1)
"no shutdown" non viene visualizzato nella configurazione in esecuzione o all'avvio.
Shutdown" viene visualizzato sia in esecuzione che all'avvio.

9396T-1(config-if)# show run int po123

!Command: show running-config interface port-channel123
!Running configuration last done at: Sun Aug 19 20:37:45 2018
!Time: Sun Aug 19 20:57:32 2018

version 8.3(1)

interface port-channel123
  switchport mode E
  switchport trunk allowed vsan 1-2
  switchport rate-mode dedicated

9396T-1(config-if)# show start int po123

!Command: show startup-config interface port-channel123
!Time: Sun Aug 19 20:57:54 2018
!Startup config saved at: Sun Aug 19 20:38:25 2018

version 8.3(1)

interface port-channel123
  switchport mode E
  switchport trunk allowed vsan 1-2
  switchport rate-mode dedicated

------------------------------------------------------------------
9396T-1(config-if)# shut
9396T-1(config-if)# show run int po123

!Command: show running-config interface port-channel123
!Running configuration last done at: Sun Aug 19 20:58:22 2018
!Time: Sun Aug 19 20:58:31 2018

version 8.3(1)

interface port-channel123
  switchport mode E
  switchport trunk allowed vsan 1-2
  shutdown       <-----------------------------------------------------
  switchport rate-mode dedicated

9396T-1(config-if)# copy run start

9396T-1(config-if)# show start int po123

!Command: show startup-config interface port-channel123
!Time: Sun Aug 19 20:59:42 2018
!Startup config saved at: Sun Aug 19 20:59:22 2018

version 8.3(1)

interface port-channel123
  switchport mode E
  switchport trunk allowed vsan 1-2
  shutdown      <-----------------------------------------------------
  switchport rate-mode dedicated

La versione 8.4(1)
"no shutdown" ora viene visualizzata nella configurazione di avvio, ma non nella configurazione in esecuzione.
Shutdown" viene visualizzato sia in esecuzione che all'avvio.

MDS9396S-1(config-if)# show run int po149

!Command: show running-config interface port-channel149
!Running configuration last done at: Wed Jan 22 09:35:26 2020
!Time: Wed Jan 22 09:53:35 2020

version 8.4(1)

interface port-channel149
  channel mode on
  switchport mode E
  switchport trunk allowed vsan 237
  switchport rate-mode dedicated
  switchport trunk mode auto

MDS9396S-1(config-if)# show start int po149

!Command: show startup-config interface port-channel149
!Time: Wed Jan 22 09:54:01 2020
!Startup config saved at: Wed Jan 22 09:35:47 2020

version 8.4(1)

interface port-channel149
  channel mode on
  switchport mode E
  switchport trunk allowed vsan 237
  switchport rate-mode dedicated
  switchport trunk mode auto
  no shutdown      <-------------------------------------

Dopo aver configurato SHUTDOWN per l'interfaccia del canale della porta:

MDS9396S-1(config-if)# shut

MDS9396S-1(config-if)# show run int po149

!Command: show running-config interface port-channel149
!Running configuration last done at: Wed Jan 22 09:54:53 2020
!Time: Wed Jan 22 09:54:58 2020

version 8.4(1)

interface port-channel149
  channel mode on
  switchport mode E
  switchport trunk allowed vsan 237
  shutdown        <-----------------------
  switchport rate-mode dedicated
  switchport trunk mode auto

MDS9396S-1(config-if)# copy run start

MDS9396S-1(config-if)# show start int po149

!Command: show startup-config interface port-channel149
!Time: Wed Jan 22 10:07:39 2020
!Startup config saved at: Wed Jan 22 09:59:57 2020

version 8.4(1)

interface port-channel149
  channel mode on
  switchport mode E
  switchport trunk allowed vsan 237
  shutdown      <-------------------------
  switchport rate-mode dedicated
  switchport trunk mode auto

 

Cause

ID bug Cisco CSCvs76682 - Il comando "no shutdown" dell'interfaccia non viene visualizzato in running-config dopo ISSU 8.4(1)

Descrizione Sintomo:
dopo l'aggiornamento a 8.4(1), il comando "no shutdown" per le interfacce dei canali delle porte visualizzate in startup-config non viene visualizzato sulla stessa interfaccia in running-config.

In questo modo, le applicazioni di gestione indicano la presenza di una differenza tra le interfacce del canale della porta in running-config e startup-config. (anche se lo stato effettivo dell'interfaccia del canale della porta è corretto)

Condizioni:
Aggiornamento alla versione 8.4(x).

Soluzione alternativa:
ISSD a un livello
precedente non interessato ("no shutdown" non viene visualizzato sulle interfacce del canale della porta in running-config o startup-config).

Ulteriore descrizione del problema:
Prima della versione 8.4(1):
"no shutdown" su un'interfaccia del canale della porta non veniva visualizzata in running-config o startup-config prima della versione 8.4.
Nell'interfaccia port-channel, config veniva visualizzato sia in running-config che in startup-config prima della versione 8.4.

In 8.4(x):
l'istruzione di configurazione dell'interfaccia "no shutdown" ora viene visualizzata nella configurazione di avvio, ma non nella configurazione di esecuzione....
L'istruzione di configurazione dell'interfaccia di arresto viene ancora visualizzata sia in running-config che in startup-config.

 

Resolution

Soluzione alternativa: Eseguire il downgrade del codice a un livello di codice precedente in cui il problema non è presente.
("No Shutdown" non viene visualizzato sulle interfacce dei canali delle porte in Running-config o Startup-Config.)

Correzione: Eseguire l'aggiornamento a NX-OS 8.4.2 o versione successiva.

 

Additional Information

Si tratta di un problema estetico, che non ha alcun impatto sulla funzione.

Fare riferimento a questo video:

 