The "symrdf failover" command returns the error: "Cannot proceed in the current RDF Consistency state except if the force flag is used"
Summary: The "symrdf failover" command returns the error: "Cannot proceed in the current RDF Consistency state except if the force flag is used."
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
The "symrdf failover" command returns the error: "Cannot proceed in the current RDF Consistency state except if the force flag is used."
Cause
Customer had enabled consistency mode on devices in this group.
This can be checked by running the following command:
C:\>symrdf -sid xxxx query -rdfg 86 Symmetrix ID : 0001976xxxxx (Microcode Version: 5978) Remote Symmetrix ID : 0001976yyyyy (Microcode Version: 5978) RDF (RA) Group Number : 86 (55) Source (R1) View Target (R2) View FLAGS --------------------------------- ------------------------ ----- ------------ ST LI ST Standard A N A Logical Sym T R1 Inv R2 Inv K Sym T R1 Inv R2 Inv RDF Pair Device Dev E Tracks Tracks S Dev E Tracks Tracks MCES STATE --------------------------------- -- ------------------------ ----- ------------ N/A 00266 RW 0 45909 NR 00266 NR 0 0 AX.E Suspended N/A 00267 RW 0 30032 NR 00267 NR 0 0 AX.E Suspended Total ------- ------- ------- ------- Track(s) 0 75941 0 0 MB(s) 0.0 4103.8 0.0 0.0 Legend for FLAGS: (M)ode of Operation : A = Async, S = Sync, D = Adaptive Copy Disk Mode : T = Active (C)onsistency State : X = Enabled, . = Disabled, M = Mixed, - = N/A (E)xempt : X = Enabled, . = Disabled, M = Mixed, - = N/A R1/R2 Device (S)ize : E = R1 EQ R2, 1 = R1 GT R2, 2 = R2 GT R1, - = N/A
When the consistency mode is enabled, you would be required to either disable it, or use the -force flag.
Resolution
The customer can use the -force flag to proceed with the command, or alternatively they can disable consistency on the relevant group:
symrdf -g <dgname> disable
Additional Information
In the Solutions Enabler Symmetrix SRDF Family CLI Product Guide, the following is noted: "If consistency is enabled on SRDF/A-capable devices within the group, then the -force option must be applied for the failover, split, and suspend commands."
Affected Products