VPLEX: Jak utworzyć wolumin wirtualny

Summary: W tym artykule bazy wiedzy opisano kroki potrzebne do utworzenia woluminu wirtualnego.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Instructions

  1. Sprawdź, czy nie ma zajętych woluminów pamięci masowej:
 VPlexcli:/> ll **/storage-volumes

/clusters/cluster-1/storage-elements/storage-volumes:
Name                                      VPD83 ID                                  Capacity  Use        Vendor  IO      Type         Thin     Provision
----------------------------------------  ----------------------------------------  --------  ---------  ------  Status  -----------  Rebuild  Type
----------------------------------------  ----------------------------------------  --------  ---------  ------  ------  -----------  -------  ---------
ESX_4                                     VPD83T3:6006048000028746073753594d303143  8.43G     used       EMC     alive   normal       true     legacy
Symm0737_0001                             VPD83T3:6006048000028746073753594d303031  8.43G     used       EMC     alive   normal       true     legacy
Symm0737_001B                             VPD83T3:6006048000028746073753594d303142  8.43G     claimed    EMC     alive   normal       true     legacy
Symm0737_001D                             VPD83T3:6006048000028746073753594d303144  8.43G     claimed    EMC     alive   normal       true     legacy
Test                                      VPD83T3:6006048000028746073753594d303041  8.43G     claimed    EMC     alive   normal       true     legacy
VPD83T3:6006048000028746073753594d303035  VPD83T3:6006048000028746073753594d303035  8.43G     unclaimed  EMC     alive   traditional  false    legacy

 

  1. Zajmij żądany wolumin pamięci masowej:
VPlexcli:/> storage-volume claim --name testA -d VPD83T3:6006048000028746073753594d303035/
Claimed 1 of 1 storage-volumes.

 

  1. Upewnij się, że przywłaszczenie woluminu pamięci masowej powiodło się:
VPlexcli:/> ll /clusters/cluster-1/storage-elements/storage-volumes

/clusters/cluster-1/storage-elements/storage-volumes:
Name                                      VPD83 ID                                  Capacity  Use        Vendor  IO      Type         Thin     Provision
----------------------------------------  ----------------------------------------  --------  ---------  ------  Status  -----------  Rebuild  Type
----------------------------------------  ----------------------------------------  --------  ---------  ------  ------  -----------  -------  ---------
ESX_4                                     VPD83T3:6006048000028746073753594d303143  8.43G     used       EMC     alive   normal       true     legacy
Symm0737_0001                             VPD83T3:6006048000028746073753594d303031  8.43G     used       EMC     alive   normal       true     legacy
Symm0737_001B                             VPD83T3:6006048000028746073753594d303142  8.43G     claimed    EMC     alive   normal       true     legacy
Symm0737_001D                             VPD83T3:6006048000028746073753594d303144  8.43G     claimed    EMC     alive   normal       true     legacy
Test                                      VPD83T3:6006048000028746073753594d303045  8.43G     claimed    EMC     alive   normal       true     legacy
testA                                     VPD83T3:6006048000028746073753594d303035  8.43G     claimed    EMC     alive   normal       false    legacy
 
  1. Utwórz zasięg z dostępnych zajętych woluminów pamięci masowej:
VPlexcli:/> extent create testA,Test

 

  1. Potwierdź pomyślnie utworzony zakres:
VPlexcli:/> ll /clusters/cluster-1/storage-elements/extents

/clusters/cluster-1/storage-elements/extents:
Name                                              StorageVolume       Capacity  Use
------------------------------------------------  ------------------  --------  -------
extent_Test_1                                     Test                8.43G     claimed
extent_testA_1                                    testA               8.43G     claimed

 

  1. Utwórz urządzenie lokalne:
VPlexcli:/> local-device create --name testA_vol --geometry raid-1 --extents /clusters/cluster-1/storage-elements/extents/extent_testA_1,/clusters/cluster-1/storage-elements/extents/extent_Test_1 --force

 

  1. Potwierdź, że utworzono urządzenie lokalne:
VPlexcli:/> ll -p **/devices

/clusters/cluster-1/devices:
Name                    Operational  Health  Block    Block  Capacity  Geometry  Visibility  Transfer  Virtual Volume
----------------------  Status       State   Count    Size   --------  --------  ----------  Size      --------------------------
----------------------  -----------  ------  -------  -----  --------  --------  ----------  --------  --------------------------
testA_vol                 ok           ok      2209680  4K     8.43G     raid-1    local       128K      -



VPlexcli:/> show-use-hierarchy /clusters/cluster-1/devices/testA_vol/
local-device: testA_vol (8.43G, raid-1, cluster-1)
  extent: extent_Test_1 (8.43G)
    storage-volume: Test (8.43G)
      logical-unit: VPD83T3:6006048000028746073753594d303045
        storage-array: EMC-SYMMETRIX-287460737
  extent: extent_testA_1 (8.43G)
    storage-volume: testA (8.43G)
      logical-unit: VPD83T3:6006048000028746073753594d303035
        storage-array: EMC-SYMMETRIX-287460737

 

  1. Tworzenie woluminu wirtualnego:
VPlexcli:/> virtual-volume create -r testA_vol

 

  1. Upewnij się, że wolumin wirtualny został utworzony pomyślnie:
VPlexcli:/> ll **/virtual-volumes
/clusters/cluster-1/virtual-volumes:
Name                        Operational  Health  Service     Block    Block  Capacity  Locality  Supporting Device       Cache Mode   Expandable  Expandable  Consistency  VPD ID
--------------------------  Status       State   Status      Count    Size   --------  --------  ----------------------  -----------  ----------  Capacity    Group        ----------------------------------------
--------------------------  -----------  ------  ----------  -------  -----  --------  --------  ----------------------  -----------  ----------  ----------  -----------  ----------------------------------------
testA_vol_vol               ok           ok      unexported  2209680  4K     8.43G     local     testA_vol             synchronous  true        0B          -            VPD83T3:6000144000000010b0026af0c08572c2


VPlexcli:/> show-use-hierarchy /clusters/cluster-1/devices/testA_vol/
virtual-volume: testA_vol_vol (8.43G, local @ cluster-1, unexported)   <-----------
  local-device: testA_vol (8.43G, raid-1, cluster-1)
    extent: extent_Test_1 (8.43G)
      storage-volume: Test (8.43G)
        logical-unit: VPD83T3:6006048000028746073753594d303045
          storage-array: EMC-SYMMETRIX-287460737
    extent: extent_testA_1 (8.43G)
      storage-volume: testA (8.43G)
        logical-unit: VPD83T3:6006048000028746073753594d303035
          storage-array: EMC-SYMMETRIX-287460737olumes


Wolumin wirtualny jest obecnie wyświetlany jako niewyeksportowany, ponieważ nie został dodany do widoku pamięci masowej.

  1. Sprawdź dostępne widoki pamięci masowej, aby dodać wolumin wirtualny do:
VPlexcli:/> ll **/storage-views

/clusters/cluster-1/exports/storage-views:
Name             Operational  initiator-ports                     virtual-volumes                                                                 port name, enabled, export status
---------------  Status       ----------------------------------  ------------------------------------------------------------------------------  ----------------------------------
---------------  -----------  ----------------------------------  ------------------------------------------------------------------------------  ----------------------------------
DELLPR510-F      ok           DELLPR510-F_HBA0                    (0,device_Symm0737_0008_1_vol,VPD83T3:6000144000000010b0026af0c085706c,8.43G),  P000000003CA00263-A0-FC02,true,ok,
                                                                  (1,ESX_4_vol,VPD83T3:6000144000000010b0026af0c08570e5,16.9G),                   P000000003CA0026A-A0-FC00,true,ok,
                                                                  (5,device_Symm0737_0007_1_vol,VPD83T3:6000144000000010b0026af0c0857071,8.43G)   P000000003CB0026A-B1-FC00,true,ok


                                                                  

  1. Dodaj wolumin wirtualny do żądanego widoku pamięci masowej:
VPlexcli:/> export storage-view addvirtualvolume --view DELLPR510-F --virtual-volumes testA_vol_vol

 

  1. Potwierdź pomyślne utworzenie woluminu:
VPlexcli:/> show-use-hierarchy /clusters/cluster-1/devices/testA_vol/
storage-view: DELLPR510-F (cluster-1)
  virtual-volume: testA_vol_vol (8.43G, local @ cluster-1, running)
    local-device: testA_vol (8.43G, raid-1, cluster-1)
      extent: extent_Test_1 (8.43G)
        storage-volume: Test (8.43G)
          logical-unit: VPD83T3:6006048000028746073753594d303045
            storage-array: EMC-SYMMETRIX-287460737
      extent: extent_testA_1 (8.43G)
        storage-volume: testA (8.43G)
          logical-unit: VPD83T3:6006048000028746073753594d303035
            storage-array: EMC-SYMMETRIX-287460737

Affected Products

VPLEX Series

Products

VPLEX Series, VPLEX VS1, VPLEX VS2, VPLEX VS6
Article Properties
Article Number: 000158420
Article Type: How To
Last Modified: 18 Sept 2025
Version:  5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.