VPLEX: Virtuaalisen äänenvoimakkuuden luominen
Summary: Tässä tietämyskannan artikkelissa on ohjeet virtuaaliaseman luomiseen.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Instructions
- Tarkista, onko lunastamattomia tallennusasemia:
VPlexcli:/> ll **/storage-volumes
/clusters/cluster-1/storage-elements/storage-volumes:
Name VPD83 ID Capacity Use Vendor IO Type Thin Provision
---------------------------------------- ---------------------------------------- -------- --------- ------ Status ----------- Rebuild Type
---------------------------------------- ---------------------------------------- -------- --------- ------ ------ ----------- ------- ---------
ESX_4 VPD83T3:6006048000028746073753594d303143 8.43G used EMC alive normal true legacy
Symm0737_0001 VPD83T3:6006048000028746073753594d303031 8.43G used EMC alive normal true legacy
Symm0737_001B VPD83T3:6006048000028746073753594d303142 8.43G claimed EMC alive normal true legacy
Symm0737_001D VPD83T3:6006048000028746073753594d303144 8.43G claimed EMC alive normal true legacy
Test VPD83T3:6006048000028746073753594d303041 8.43G claimed EMC alive normal true legacy
VPD83T3:6006048000028746073753594d303035 VPD83T3:6006048000028746073753594d303035 8.43G unclaimed EMC alive traditional false legacy
- Lunasta haluamasi tallennusasema:
VPlexcli:/> storage-volume claim --name testA -d VPD83T3:6006048000028746073753594d303035/
Claimed 1 of 1 storage-volumes.
- Varmista, että tallennusaseman varaaminen onnistui:
VPlexcli:/> ll /clusters/cluster-1/storage-elements/storage-volumes
/clusters/cluster-1/storage-elements/storage-volumes:
Name VPD83 ID Capacity Use Vendor IO Type Thin Provision
---------------------------------------- ---------------------------------------- -------- --------- ------ Status ----------- Rebuild Type
---------------------------------------- ---------------------------------------- -------- --------- ------ ------ ----------- ------- ---------
ESX_4 VPD83T3:6006048000028746073753594d303143 8.43G used EMC alive normal true legacy
Symm0737_0001 VPD83T3:6006048000028746073753594d303031 8.43G used EMC alive normal true legacy
Symm0737_001B VPD83T3:6006048000028746073753594d303142 8.43G claimed EMC alive normal true legacy
Symm0737_001D VPD83T3:6006048000028746073753594d303144 8.43G claimed EMC alive normal true legacy
Test VPD83T3:6006048000028746073753594d303045 8.43G claimed EMC alive normal true legacy
testA VPD83T3:6006048000028746073753594d303035 8.43G claimed EMC alive normal false legacy
- Luo kiintiö käytettävissä olevista väitetyistä tallennusasemista:
VPlexcli:/> extent create testA,Test
- Vahvista, että laajuus on luotu:
VPlexcli:/> ll /clusters/cluster-1/storage-elements/extents
/clusters/cluster-1/storage-elements/extents:
Name StorageVolume Capacity Use
------------------------------------------------ ------------------ -------- -------
extent_Test_1 Test 8.43G claimed
extent_testA_1 testA 8.43G claimed
- Luo paikallinen laite:
VPlexcli:/> local-device create --name testA_vol --geometry raid-1 --extents /clusters/cluster-1/storage-elements/extents/extent_testA_1,/clusters/cluster-1/storage-elements/extents/extent_Test_1 --force
- Varmista, että paikallisen laitteen luonti onnistui:
VPlexcli:/> ll -p **/devices
/clusters/cluster-1/devices:
Name Operational Health Block Block Capacity Geometry Visibility Transfer Virtual Volume
---------------------- Status State Count Size -------- -------- ---------- Size --------------------------
---------------------- ----------- ------ ------- ----- -------- -------- ---------- -------- --------------------------
testA_vol ok ok 2209680 4K 8.43G raid-1 local 128K -
VPlexcli:/> show-use-hierarchy /clusters/cluster-1/devices/testA_vol/
local-device: testA_vol (8.43G, raid-1, cluster-1)
extent: extent_Test_1 (8.43G)
storage-volume: Test (8.43G)
logical-unit: VPD83T3:6006048000028746073753594d303045
storage-array: EMC-SYMMETRIX-287460737
extent: extent_testA_1 (8.43G)
storage-volume: testA (8.43G)
logical-unit: VPD83T3:6006048000028746073753594d303035
storage-array: EMC-SYMMETRIX-287460737
- Luo virtuaalinen tallennustila:
VPlexcli:/> virtual-volume create -r testA_vol
- Vahvista virtuaalilevyn luomisen onnistuminen:
VPlexcli:/> ll **/virtual-volumes
/clusters/cluster-1/virtual-volumes:
Name Operational Health Service Block Block Capacity Locality Supporting Device Cache Mode Expandable Expandable Consistency VPD ID
-------------------------- Status State Status Count Size -------- -------- ---------------------- ----------- ---------- Capacity Group ----------------------------------------
-------------------------- ----------- ------ ---------- ------- ----- -------- -------- ---------------------- ----------- ---------- ---------- ----------- ----------------------------------------
testA_vol_vol ok ok unexported 2209680 4K 8.43G local testA_vol synchronous true 0B - VPD83T3:6000144000000010b0026af0c08572c2
VPlexcli:/> show-use-hierarchy /clusters/cluster-1/devices/testA_vol/
virtual-volume: testA_vol_vol (8.43G, local @ cluster-1, unexported) <-----------
local-device: testA_vol (8.43G, raid-1, cluster-1)
extent: extent_Test_1 (8.43G)
storage-volume: Test (8.43G)
logical-unit: VPD83T3:6006048000028746073753594d303045
storage-array: EMC-SYMMETRIX-287460737
extent: extent_testA_1 (8.43G)
storage-volume: testA (8.43G)
logical-unit: VPD83T3:6006048000028746073753594d303035
storage-array: EMC-SYMMETRIX-287460737olumes
Virtuaaliasema näkyy tällä hetkellä viemättömänä, koska sitä ei ole lisätty tallennusnäkymään.
- Tarkista käytettävissä olevat tallennustilanäkymät lisätäksesi virtuaalisen tallennustilan:
VPlexcli:/> ll **/storage-views
/clusters/cluster-1/exports/storage-views:
Name Operational initiator-ports virtual-volumes port name, enabled, export status
--------------- Status ---------------------------------- ------------------------------------------------------------------------------ ----------------------------------
--------------- ----------- ---------------------------------- ------------------------------------------------------------------------------ ----------------------------------
DELLPR510-F ok DELLPR510-F_HBA0 (0,device_Symm0737_0008_1_vol,VPD83T3:6000144000000010b0026af0c085706c,8.43G), P000000003CA00263-A0-FC02,true,ok,
(1,ESX_4_vol,VPD83T3:6000144000000010b0026af0c08570e5,16.9G), P000000003CA0026A-A0-FC00,true,ok,
(5,device_Symm0737_0007_1_vol,VPD83T3:6000144000000010b0026af0c0857071,8.43G) P000000003CB0026A-B1-FC00,true,ok
- Lisää virtuaalinen asema haluttuun tallennusnäkymään:
VPlexcli:/> export storage-view addvirtualvolume --view DELLPR510-F --virtual-volumes testA_vol_vol
- Vahvista taltion luonti:
VPlexcli:/> show-use-hierarchy /clusters/cluster-1/devices/testA_vol/
storage-view: DELLPR510-F (cluster-1)
virtual-volume: testA_vol_vol (8.43G, local @ cluster-1, running)
local-device: testA_vol (8.43G, raid-1, cluster-1)
extent: extent_Test_1 (8.43G)
storage-volume: Test (8.43G)
logical-unit: VPD83T3:6006048000028746073753594d303045
storage-array: EMC-SYMMETRIX-287460737
extent: extent_testA_1 (8.43G)
storage-volume: testA (8.43G)
logical-unit: VPD83T3:6006048000028746073753594d303035
storage-array: EMC-SYMMETRIX-287460737