Cisco MDS:System Manager 檔案儲存裝置使用量意外高至達到 100%

Summary: System Manager 檔案儲存裝置使用量意外高至達到 100%。這可能會影響系統功能。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

  • 修改區域 (區域認可)

  • 區域認可作業失敗,而且在相同網狀架構內執行 NX OS 6.2(5) 的 MDS-9513 上發現下列錯誤:

    2018 Feb 17 23:27:06 Switch09 %SYSMGR-2-SERVICE_CRASHED: Service "zone" (PID 3632) hasn't caught signal 11 (core will be saved).
    2018 Feb 17 23:27:07 Switch09 %CALLHOME-2-EVENT: SW_CRASH zone in slot 7 crashed with crash type : stateful crash
    2018 Feb 17 23:27:32 Switch09 %SYSMGR-2-CORE_SAVE_FAILED: zip_copy_file_to_logflash: PID 28495 with message Failed to copy 0x701_zone_core.3632 to logflash. Error file error (srcerr 0x0 dsterr 0x807b001c) .
    ...
    2018 Feb 17 23:46:58 Switch09 %SYSMGR-2-LAST_CORE_BASIC_TRACE: : PID 30106 with message non-sysmgr(non-sysmgr) crashed, core will be saved .
    2018 Feb 17 23:46:59 Switch09 %SYSMGR-2-LAST_CORE_BASIC_TRACE: : PID 30119 with message non-sysmgr(non-sysmgr) crashed, core will be saved .
    2018 Feb 17 23:46:59 Switch09 %SYSMGR-2-LAST_CORE_BASIC_TRACE: : PID 30126 with message non-sysmgr(non-sysmgr) crashed, core will be saved .
    2018 Feb 18 00:02:24 Switch09 %SYSMGR-2-LAST_CORE_BASIC_TRACE: : PID 31135 with message non-sysmgr(non-sysmgr) crashed, core will be saved .
    2018 Feb 18 00:02:24 Switch09 %SYSMGR-2-LAST_CORE_BASIC_TRACE: : PID 31144 with message non-sysmgr(non-sysmgr) crashed, core will be saved .
    2018 Feb 18 00:02:24 Switch09 %SYSMGR-2-LAST_CORE_BASIC_TRACE: : PID 31151 with message non-sysmgr(non-sysmgr) crashed, core will be saved .
    .....
    2018 Feb 18 05:08:35 Switch09 %SYSMGR-3-VAR_SYSMGR_FULL: System Manager file storage usage is unexpectedly high at 100%. This may impact system functions.
    2018 Feb 18 05:11:35 Switch09 last message repeated 1 time
  • 核心傾印已產生

    `show cores`
    Module  Instance  Process-name     PID       Date(Year-Month-Day Time)
    ------  --------  ---------------  --------  -------------------------
    7       1         zone             3632      2018-02-17 23:27:06
  • /var/sysmgr 檔案系統顯示 100% 的使用率:

    `show system internal flash`
    Mount-on 1K-blocks Used Available Use% Filesystem
    ....
    /var/sysmgr 204800 204800 0 100 none

 

Cause

由於核心傾印已損毀,因此無法判定根本原因。

 

Resolution

從交換器複製現有的核心傾印檔案,並執行「clear cores」,即清除 /var/sysmgr 檔案系統。

範例:

Switch09# clear cores
Switch09# show cores
Module Instance Process-name PID Date(Year-Month-Day Time)
------ -------- --------------- -------- -------------------------
Switch09#

Switch09# show system internal dir /var/sysmgr
./ 320
../ 220
core_handling.log 2883
ssh/ 40
non-sysmgr/ 40
sysmgr-subproc/ 40
xml/ 40
vsh/ 40
remote/ 100
tmp_logs/ 40
rev-gsync/ 40
startup-cfg/ 240
tmp/ 40
ftp/ 480
work/ 100
logs/ 40

Switch09# show system internal flash
Mount-on 1K-blocks Used Available Use% Filesystem
...
/var/sysmgr 204800 60 204740 1 none

 