PowerStore:叢集網路驗證失敗 - 無法透過原生 VLAN 位址的 ICMP ping 從節點 B 連線到節點 A
Summary: 無法透過原生 VLAN 位址的 ICMP ping 從節點 B 連線至節點 A。這會導致無法安裝 NAS 服務。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
在新的 PowerStore 部署中,在叢集建立 (ICW) 期間,網路驗證檢查會出現下列錯誤:
reason":{"code":"0xE0E800300010","severity":"Error","message_l10n":"The node A is not reachable from the node B via ICMP ping of native VLAN address. This will prevent NAS services from being installed.","arguments":["A","B"]},"resolution":{"code":"0xE0E800300010.resolution","severity":"Info","message_l10n":"Ensure that the physical switches are configured properly."},"applianceId":"8H02643"}, {"reason":{"code":"0xE0E800300010","severity":"Error","message_l10n":"The node B is not reachable from the node A via ICMP ping of native VLAN address. This will prevent NAS services from being installed.","arguments":["B","A"]},"resolution":{"code":"0xE0E800300010.resolution","severity":"Info","message_l10n":"Ensure that the physical switches are configured properly."},"applianceId":"8H02643"}, {"reason":{"code":"0xE0E70060000E","severity":"Warning","message_l10n":"Onboard management ports are connected to the same ethernet switch 2c:33:11:d3:a9:80.","arguments":["2c:33:11:d3:a9:80"]},"resolution":{"code":"0xE0E70060000E.resolution","severity":"Info","message_l10n":"You may cable both nodes to the same switch, if you cannot provision two management switches. But, for high availability purposes, it is recommended that you configure two switches, and connect nodes A and B of the appliance to alternate switches."},"applianceId":"8H0264
Cause
資料交換器上需要 SDNAS/NAS 服務 IPv6 功能。
在無 Dell TOR 中,可能無法依要求啟用 IPv6。
Resolution
客戶和支援/部署服務可與網路管理員合作,確保完成下列事項:
-
NAS 作業必須啟用 IPv6。
自 1.0.3 SP3 起,叢集內部 IPv6 通訊會使用內部實體層,而非 LACP 連接埠通道。但是,若要進行 NAS 作業,部署統一組態仍需要在 LACP 上安裝 IPV6。 -
此外,LACP 連接埠通道組態上也必須允許原生 VLAN。
以下為組態範例,顯示 VLAN ID 不同時允許的其他 VLAN:interface port-channel70 description "Connected to New SAN" switchport switchport mode trunk switchport trunk native vlan 999 switchport trunk allowed vlan 5,10,50 ==> add 999 here vpc 70 interface port-channel71 description "Connected to New SAN" switchport switchport mode trunk switchport trunk native vlan 900 switchport trunk allowed vlan 5,10,50 ==> add 900 here vpc 71
Additional Information
如需進一步的網路需求,請參閱下列官方說明文件指南。
注意:本指南指的是 Dell 機架頂端組態 (不適用於其他交換器廠商,但在組態方面應類似)
https://www.dell.com/support/manuals/en-us/powerstore-1000t/pwrstrt-ntwkg/running-configuration-of-powerswitch-series-used-in-powerstore-t-model-deployments?guid=guid-efb5a236-626a-4f64-9367-b3f488405024⟨=en-us
Affected Products
PowerStoreArticle Properties
Article Number: 000185874
Article Type: Solution
Last Modified: 19 Nov 2025
Version: 4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.