PowerStore:叢集網路驗證失敗 - 無法透過原生 VLAN 位址的 ICMP ping 從節點 B 連線到節點 A

Summary: 無法透過原生 VLAN 位址的 ICMP ping 從節點 B 連線至節點 A。這會導致無法安裝 NAS 服務。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

在新的 PowerStore 部署中,在叢集建立 (ICW) 期間,網路驗證檢查會出現下列錯誤:

reason":{"code":"0xE0E800300010","severity":"Error","message_l10n":"The node A is not reachable from the node B via ICMP ping of native VLAN address. This will prevent NAS services from being installed.","arguments":["A","B"]},"resolution":{"code":"0xE0E800300010.resolution","severity":"Info","message_l10n":"Ensure that the physical switches are configured properly."},"applianceId":"8H02643"}, {"reason":{"code":"0xE0E800300010","severity":"Error","message_l10n":"The node B is not reachable from the node A via ICMP ping of native VLAN address. This will prevent NAS services from being installed.","arguments":["B","A"]},"resolution":{"code":"0xE0E800300010.resolution","severity":"Info","message_l10n":"Ensure that the physical switches are configured properly."},"applianceId":"8H02643"}, {"reason":{"code":"0xE0E70060000E","severity":"Warning","message_l10n":"Onboard management ports are connected to the same ethernet switch 2c:33:11:d3:a9:80.","arguments":["2c:33:11:d3:a9:80"]},"resolution":{"code":"0xE0E70060000E.resolution","severity":"Info","message_l10n":"You may cable both nodes to the same switch, if you cannot provision two management switches. But, for high availability purposes, it is recommended that you configure two switches, and connect nodes A and B of the appliance to alternate switches."},"applianceId":"8H0264

 

Cause

資料交換器上需要 SDNAS/NAS 服務 IPv6 功能。
在無 Dell TOR 中,可能無法依要求啟用 IPv6。

 

Resolution

客戶和支援/部署服務可與網路管理員合作,確保完成下列事項:

  1. NAS 作業必須啟用 IPv6。
    自 1.0.3 SP3 起,叢集內部 IPv6 通訊會使用內部實體層,而非 LACP 連接埠通道。但是,若要進行 NAS 作業,部署統一組態仍需要在 LACP 上安裝 IPV6。

  2. 此外,LACP 連接埠通道組態上也必須允許原生 VLAN。
    以下為組態範例,顯示 VLAN ID 不同時允許的其他 VLAN:

    interface port-channel70
      description "Connected to New SAN"
      switchport
      switchport mode trunk
      switchport trunk native vlan 999          
      switchport trunk allowed vlan 5,10,50      ==> add 999 here
      vpc 70
    interface port-channel71
      description "Connected to New SAN"
      switchport
      switchport mode trunk
      switchport trunk native vlan 900
      switchport trunk allowed vlan 5,10,50      ==> add 900 here
      vpc 71

 

Additional Information

如需進一步的網路需求,請參閱下列官方說明文件指南。

注意:本指南指的是 Dell 機架頂端組態 (不適用於其他交換器廠商,但在組態方面應類似)

https://www.dell.com/support/manuals/en-us/powerstore-1000t/pwrstrt-ntwkg/running-configuration-of-powerswitch-series-used-in-powerstore-t-model-deployments?guid=guid-efb5a236-626a-4f64-9367-b3f488405024⟨=en-us

 

Affected Products