PowerStore:群集网络验证失败— 通过本机 VLAN 地址的 ICMP ping,无法从节点 B 访问节点 A

Summary: 通过本机 VLAN 地址的 ICMP ping,无法从节点 B 到达节点 A。这会阻止安装 NAS 服务。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

在新的 PowerStore 部署中,在群集创建 (ICW) 期间,网络验证检查再次显示以下错误:

reason":{"code":"0xE0E800300010","severity":"Error","message_l10n":"The node A is not reachable from the node B via ICMP ping of native VLAN address. This will prevent NAS services from being installed.","arguments":["A","B"]},"resolution":{"code":"0xE0E800300010.resolution","severity":"Info","message_l10n":"Ensure that the physical switches are configured properly."},"applianceId":"8H02643"}, {"reason":{"code":"0xE0E800300010","severity":"Error","message_l10n":"The node B is not reachable from the node A via ICMP ping of native VLAN address. This will prevent NAS services from being installed.","arguments":["B","A"]},"resolution":{"code":"0xE0E800300010.resolution","severity":"Info","message_l10n":"Ensure that the physical switches are configured properly."},"applianceId":"8H02643"}, {"reason":{"code":"0xE0E70060000E","severity":"Warning","message_l10n":"Onboard management ports are connected to the same ethernet switch 2c:33:11:d3:a9:80.","arguments":["2c:33:11:d3:a9:80"]},"resolution":{"code":"0xE0E70060000E.resolution","severity":"Info","message_l10n":"You may cable both nodes to the same switch, if you cannot provision two management switches. But, for high availability purposes, it is recommended that you configure two switches, and connect nodes A and B of the appliance to alternate switches."},"applianceId":"8H0264

 

Cause

SDNAS/NAS 服务需要数据交换机上的 IPv6 功能。
在“无”Dell TOR 中,有可能未按要求启用 IPv6。

 

Resolution

客户和支持/部署服务可以与网络管理员合作,以确保以下各项:

  1. NAS作需要启用 IPv6。
    从 1.0.3 SP3 开始,群集内 IPv6 通信使用内部物理层,而不是 LACP 端口通道。但是,部署统一配置仍需要在 LACP 上使用 IPV6,以便进行 NAS作。

  2. 此外,必须在 LACP 端口通道配置上允许使用本机 VLAN。
    下面是一个配置示例,显示了在 vlan ID 不同时允许的其他 VLAN:

    interface port-channel70
      description "Connected to New SAN"
      switchport
      switchport mode trunk
      switchport trunk native vlan 999          
      switchport trunk allowed vlan 5,10,50      ==> add 999 here
      vpc 70
    interface port-channel71
      description "Connected to New SAN"
      switchport
      switchport mode trunk
      switchport trunk native vlan 900
      switchport trunk allowed vlan 5,10,50      ==> add 900 here
      vpc 71

 

Additional Information

您可以参阅以下官方文档指南,了解进一步的网络要求。

提醒:本指南指的是戴尔架顶式配置(不适用于其他交换机供应商,但配置方面应类似)

https://www.dell.com/support/manuals/en-us/powerstore-1000t/pwrstrt-ntwkg/running-configuration-of-powerswitch-series-used-in-powerstore-t-model-deployments?guid=guid-efb5a236-626a-4f64-9367-b3f488405024⟨=en-us

 