在搭載 X710 NIC 的 14G 伺服器上,PowerFlex PXE 開機失敗

Summary: 當 Intel X710 NIC 存在時,節點無法在部署期間進行 PXE 引導。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

  • 作業系統安裝會在部署期間逾時。
  • 當節點進行 PXE 開機時,您會在 iDRAC 主控台看到「連線逾時」訊息。
PXE_boot_iDRAC_console
  • rackserver-service tag<>_exception.log 檔案中的錯誤訊息:
#<ASM::UserException: The installation of the operating system for node 3Z5ZDF3 10.5.42.165 timed out.>

/opt/asm-deployer/lib/asm/razor.rb:314:in `block_until_task_complete'
/opt/asm-deployer/lib/asm/type/server.rb:3428:in `razor_block_until'
/opt/asm-deployer/lib/asm/type/server.rb:1687:in `provision_server!'
/opt/asm-deployer/lib/asm/service_deployment.rb:5146:in `process_server_with_types'
/opt/asm-deployer/lib/asm/service_deployment.rb:2949:in `process_server'
/opt/asm-deployer/lib/asm/service_deployment.rb:1409:in `block in create_component_thread'
 
 

Cause

  • 這是在 PXE 安裝過程之前將 LACP 連接埠通道 (啟用回退) 新增至 PXE 交換器介面的變更回歸。
  • 在此變更之前,已使用中繼連接埠。新方法在 Mellanox NIC 上運作良好,但在 Intel X710 NIC 上似乎失敗。

Resolution

  • 當節點開始 PXE 引導時,您會在 iDRAC 主控台上看到連線逾時訊息。
  • 現在從 PXE 交換器介面移除連接埠通道
    • 確定部署中每個節點用於 PXE 網路的埠,並查找在每個埠上配置的通道組 #(示例如下):
port_config
  • 在介面上進入第一個節點的組態模式,並執行下列命令:
no channel-group <channel-group #> mode active
  • 對服務中的每個節點重複上述步驟。
  • 將您的組態變更儲存在交換器上
copy run start
  • 當節點重新開機時 (由於 PXE 開機失敗,應處於開機迴圈中),PXE 安裝將會完成。
  • 如果服務已失敗,則必須更改埠通道並重試服務。
  • 將節點重新開機,並確定已使用 PXE 完整安裝 ESX,然後再重試服務。

Affected Products

PowerFlex rack
Article Properties
Article Number: 000195206
Article Type: Solution
Last Modified: 26 May 2025
Version:  4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.