PowerFlex Manager: En uventet "State"-nøgle returneres i svaret, når der forespørges på fysiske diske ved hjælp af REST API
Summary: Feltværdierne for PhysicalDisk forventes at afspejle WSMAN's DCIM_PhysicalDiskView detaljer, og "State" vises ikke i den.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Instructions
Når du kører en API-forespørgsel for feltet PhysicalDisk, indeholder svaret en "tilstandsnøgle", der ikke vises i WSMAN-lignende forespørgselskommando, DCIM_PhysicalDiskView, som vist i eksemplerne nedenfor.
"Tilstand" -nøglen blev tilføjet ved et uheld, da den ikke er indstillet eller brugt af nogen komponent eller enhed i systemet.
"Stat" -nøglen og forskellige værdier bør ignoreres sikkert.
Eksempel på API JSON-svar
$ curl -s -k --location -X GET -H "x-dell-auth-key: $apiKey" -H "x-dell-auth-signature: $signature" -H "x-dell-auth-timestamp: $timestamp" "https://10.1.1.1/Api/V1/Server"
...
{
"id" : "8a6af86585e8ff530186010d3a681020",
"fqdd" : "NonRAID.Integrated.1-1",
"productName" : "Dell HBA330 Mini",
"deviceDescription" : "Integrated Storage Controller 1",
"firmwareVersion" : "16.17.01.00",
"driverVersion" : null,
"pciSlot" : 1,
"numPhysDisks" : 8,
"cacheSizeInMB" : 0,
"physicalDisks" : [ {
"fqdd" : "Disk.Bay.4:Enclosure.Internal.0-1:NonRAID.Integrated.1-1",
"deviceDescription" : "Disk 4 in Backplane 1 of Integrated Storage Controller 1",
"raidStatus" : "NON_RAID",
"securityState" : "NOT_CAPABLE",
"busProtocol" : "SAS",
"mediaType" : "SSD",
"size" : 1920383409664,
"driveNumber" : 4,
"deviceSerial" : "17T0A027TF2E",
"manufacturer" : "TOSHIBA",
"model" : "PX05SRB192Y",
"remainingRatedWriteEndurance" : "95",
"rollUpStatus" : "1",
"predictiveFailureState" : "0",
"state" : null,
"supportedEncryptionTypes" : [ "None" ],
"hotSpareStatus" : "No"
},
...
Eksempel på WSMAN-kommandosvar
C:\Users\Administrator>winrm e cimv2/root/dcim/dcim/DCIM_PhysicalDiskView -u:root -p:Abcd@1234 -r:https://10.1.1.1/wsman -auth:basic -encoding:utf-8 -SkipCACheck -SkipCNCheck
...
DCIM_PhysicalDiskView
BlockSizeInBytes = 512
BusProtocol = 6
ConfigLockdownCapable = 0
ConfigLockdownState = 0
Connector = 0
DeviceDescription = Disk 4 in Backplane 1 of Integrated Storage Controller 1
DriveFormFactor = 2
FQDD = Disk.Bay.4:Enclosure.Internal.0-1:NonRAID.Integrated.1-1
ForeignKeyIdentifier = null
FreeSizeInBytes = 0
HotSpareStatus = 0
InstanceID = Disk.Bay.4:Enclosure.Internal.0-1:NonRAID.Integrated.1-1
LastSystemInventoryTime = 20221102201007.000000+000
LastUpdateTime = 20220831001933.000000+000
Manufacturer = TOSHIBA
ManufacturingDay = 0
ManufacturingWeek = 7
ManufacturingYear = 2020
MaxCapableSpeed = 4
MediaType = 1
Model = KPM5XVUG960G
OperationName = None
OperationPercentComplete = 0
PPID = PH0WFGTHTBPKK02B1BK2A02
PredictiveFailureState = 0
PrimaryStatus = 1
RAIDType = 0
RaidStatus = 8
RemainingRatedWriteEndurance = 100
Revision = B01C
RollupStatus = 1
SASAddress = 58CE38EE20E0FF6A
SecurityState = 0
SerialNumber = 20B0A004TP5F
SizeInBytes = 960197123584
Slot = 4
SupportedEncryptionTypes = Cryptographic Erase Capable
SystemEraseCapability = 2
T10PICapability = 0
UpdateLockdownCapable = 0
UpdateLockdownState = 0
UsedSizeInBytes = 0Affected Products
PowerFlex rack, PowerFlex Appliance, PowerFlex custom nodeArticle Properties
Article Number: 000214767
Article Type: How To
Last Modified: 13 Feb 2025
Version: 2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.