对 PhysicalDisk 字段运行 API 查询时,响应包含一个“state”键,该键不会出现在 WSMAN 类似的查询命令 DCIM_PhysicalDiskView 中,如下面的示例所示。
“state”键是意外添加的,因为它未由系统中的任何组件或实体设置或使用。
应安全地忽略“state”键和各种值。
API JSON 响应示例
$ curl -s -k --location -X GET -H "x-dell-auth-key: $apiKey" -H "x-dell-auth-signature: $signature" -H "x-dell-auth-timestamp: $timestamp" "https://10.1.1.1/Api/V1/Server"
...
{
"id" : "8a6af86585e8ff530186010d3a681020",
"fqdd" : "NonRAID.Integrated.1-1",
"productName" : "Dell HBA330 Mini",
"deviceDescription" : "Integrated Storage Controller 1",
"firmwareVersion" : "16.17.01.00",
"driverVersion" : null,
"pciSlot" : 1,
"numPhysDisks" : 8,
"cacheSizeInMB" : 0,
"physicalDisks" : [ {
"fqdd" : "Disk.Bay.4:Enclosure.Internal.0-1:NonRAID.Integrated.1-1",
"deviceDescription" : "Disk 4 in Backplane 1 of Integrated Storage Controller 1",
"raidStatus" : "NON_RAID",
"securityState" : "NOT_CAPABLE",
"busProtocol" : "SAS",
"mediaType" : "SSD",
"size" : 1920383409664,
"driveNumber" : 4,
"deviceSerial" : "17T0A027TF2E",
"manufacturer" : "TOSHIBA",
"model" : "PX05SRB192Y",
"remainingRatedWriteEndurance" : "95",
"rollUpStatus" : "1",
"predictiveFailureState" : "0",
"state" : null,
"supportedEncryptionTypes" : [ "None" ],
"hotSpareStatus" : "No"
},
...
WSMAN 命令响应示例
C:\Users\Administrator>winrm e cimv2/root/dcim/dcim/DCIM_PhysicalDiskView -u:root -p:Abcd@1234 -r:https://10.1.1.1/wsman -auth:basic -encoding:utf-8 -SkipCACheck -SkipCNCheck
...
DCIM_PhysicalDiskView
BlockSizeInBytes = 512
BusProtocol = 6
ConfigLockdownCapable = 0
ConfigLockdownState = 0
Connector = 0
DeviceDescription = Disk 4 in Backplane 1 of Integrated Storage Controller 1
DriveFormFactor = 2
FQDD = Disk.Bay.4:Enclosure.Internal.0-1:NonRAID.Integrated.1-1
ForeignKeyIdentifier = null
FreeSizeInBytes = 0
HotSpareStatus = 0
InstanceID = Disk.Bay.4:Enclosure.Internal.0-1:NonRAID.Integrated.1-1
LastSystemInventoryTime = 20221102201007.000000+000
LastUpdateTime = 20220831001933.000000+000
Manufacturer = TOSHIBA
ManufacturingDay = 0
ManufacturingWeek = 7
ManufacturingYear = 2020
MaxCapableSpeed = 4
MediaType = 1
Model = KPM5XVUG960G
OperationName = None
OperationPercentComplete = 0
PPID = PH0WFGTHTBPKK02B1BK2A02
PredictiveFailureState = 0
PrimaryStatus = 1
RAIDType = 0
RaidStatus = 8
RemainingRatedWriteEndurance = 100
Revision = B01C
RollupStatus = 1
SASAddress = 58CE38EE20E0FF6A
SecurityState = 0
SerialNumber = 20B0A004TP5F
SizeInBytes = 960197123584
Slot = 4
SupportedEncryptionTypes = Cryptographic Erase Capable
SystemEraseCapability = 2
T10PICapability = 0
UpdateLockdownCapable = 0
UpdateLockdownState = 0
UsedSizeInBytes = 0Affected Products
PowerFlex rack, PowerFlex Appliance, PowerFlex custom nodeArticle Properties
Article Number: 000214767
Article Type: How To
Last Modified: 13 Feb 2025
Version: 2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.