PowerFlex 3.X Under NDU krasjer en SDS under utføring av mgStorageRegion_CopyFromBuffer-funksjonen

Summary: SDS krasjer under funksjon mgStorageRegion_CopyFromBuffer

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

 - Oppgrader fra 3,0 til 3,6

 - SDS avslutter øyeblikkelig vedlikeholdsmodus (IMM)  

- Kontrollsum for Inflight er aktivert.  

SDS krasjer med følgende panikk: 

2022/12/20 10:22:18.543129 Panic in file /data/build/workspace/ScaleIO-Common-Job/src/tgt/storage/mg_impl/mg_storage_region.c, line 4188, function mgStorageRegion_CopyFromBuffer, PID 13108.Panic Expression !(bufferSizeInBytes != ((sizeInLbs) * (512))) PANIC_ID_tgt_1517847817759.
/opt/emc/scaleio/sds/bin/sds-3.6.400.107(mosDbg_PanicPrepare+0x13a) [0x93ab8a]
/opt/emc/scaleio/sds/bin/sds-3.6.400.107(mgStorageRegion_CopyFromBuffer+0x1a7) [0x810477]
/opt/emc/scaleio/sds/bin/sds-3.6.400.107(mgStorageRegion_CopyFromCachedBuffer+0x33) [0x810873]
/opt/emc/scaleio/sds/bin/sds-3.6.400.107(storageRegion_CopyFromCachedBuffer+0xde) [0x4d3f3e]
/opt/emc/scaleio/sds/bin/sds-3.6.400.107(mgStorageRegion_ReadFromSyncBuf+0x45) [0x4d4a85]
/opt/emc/scaleio/sds/bin/sds-3.6.400.107(raidComb_ReadFromRemoteUntilEntireRegionIsAcquired+0x451) [0x74e021]
/opt/emc/scaleio/sds/bin/sds-3.6.400.107(raidComb_ReadVolumeFromRemote+0x3ae) [0x74e8ee]
/opt/emc/scaleio/sds/bin/sds-3.6.400.107(raidReverseRebuild_LoopAndCopy+0x140f) [0x75518f]
/opt/emc/scaleio/sds/bin/sds-3.6.400.107(raidReverseRebuild_Start+0xb56) [0x7583c6]
/opt/emc/scaleio/sds/bin/sds-3.6.400.107(raidSyncPool_StartJob+0x375) [0x5e3145]

Kontrollsumfunksjonen for Inflight er aktivert i lagringsgruppen(e):

Storage Pool durpsdsc7p8pool1 (Id: 469b0f6800000007) has 7 volumes and 236.9 TB (242550 GB) free net capacity. 2.5 PB (2524 TB) volume allocation limit.
...
Inflight Checksum: Enabled
...

 

Innvirkning

SDS krasjer og kan ikke avslutte IMM. Hvis oppgraderingen ikke kan fortsette under en oppgradering.

Cause

På grunn av å være et kanttilfelle og det faktum at det er en veldig utdatert versjon som ikke lenger støttes, er det viktig å implementere løsningen beskrevet i løsningsdelen nedenfor.

Resolution

Deaktiver kontrollsummen for Inflight i lagringsutvalget som SDS bidrar til:

1) Spør alle SDS-er for å få SDS-navnet/ID-en:

[root@nestedsvm2 ~]# scli --query_all_sds
Query-all-SDS returned 3 SDS nodes.

Protection Domain 8eeacbf900000000 Name: pd1
SDS ID: ab471ceb00000002 Name: svm103 State: Connected, Joined IP: 15.15.15.103 Port: 7072 Version: 3.6.500
SDS ID: ab471cea00000001 Name: svm102 State: Connected, Joined IP: 15.15.15.102 Port: 7072 Version: 3.6.500
SDS ID: ab471ce800000000 Name: svm101 State: Connected, Joined IP: 15.15.15.101 Port: 7072 Version: 3.6.500

2) Spør SDS med enten navn / id og se etter "Storage Pool: ":

 Merk: lagringsutvalget/-ene det bidrar med enheter til; i dette tilfellet er det bare én, som er navnet Storage Pool "SP1."

[root@nestedsvm2 ~]# scli --query_sds --sds_id ab471ceb00000002 | grep -i 'storage pool:'
         1: Storage Pool: sp1  inflight requests factor: 115, inflight bandwidth factor 115
                Storage Pool: sp1, Capacity: 198 GB, State: Normal
                Storage Pool: sp1, Capacity: 98 GB, State: Normal
                Storage Pool: sp1, Capacity: 98 GB, State: Normal

3) Spørring Storage Pool og se etter "Inflight Checksum: ":

[root@nestedsvm2 ~]# scli --query_storage_pool --storage_pool_name sp1 --protection_domain_name pd1 | grep -i 'Inflight checksum'
        Inflight Checksum: Enabled

3.a) For å deaktivere kontrollsummen for Inflight, kan den gjøres ved hjelp av scli eller i presentasjonsserveren. For å deaktivere den ved hjelp av scli, kjør kommandoen nedenfor:

[root@nestedsvm2 ~]# scli --set_checksum_mode --protection_domain_name pd1 --storage_pool_name sp1 --disable_inflight_checksum
Checksum mode modified successfully

3.b) Gå til Lagringsutvalg i Presentasjonsserver > , velg Lagringsutvalg > Endre > Generelt > , fjern avmerkingen for "Aktiver kontrollsum for Inflight" > gjelder.  

 

 Berørte versjoner

PowerFlex 3.5.x

 PowerFlex 3.6.x

Affected Products

PowerFlex appliance connectivity

Products

PowerFlex rack, VxFlex Ready Nodes, PowerFlex custom node, PowerFlex appliance R650, PowerFlex appliance R6525, PowerFlex appliance R660, PowerFlex appliance R6625, Powerflex appliance R750, PowerFlex appliance R760, PowerFlex appliance R7625 , PowerFlex appliance R640, PowerFlex appliance R740XD, PowerFlex appliance R7525, PowerFlex appliance R840 ...
Article Properties
Article Number: 000225317
Article Type: Solution
Last Modified: 03 Feb 2025
Version:  3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.