VxRail 上的 VCF:升級在 10% 時失敗,錯誤訊息「錯誤:null 詳細資料:PartnerUpgradeActionDetail...”
Summary: 升級在 10% 時失敗,發生錯誤。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
升級在 10% 時失敗,並顯示錯誤:
Error: null Details: PartnerUpgradeActionDetail(action=Failed to upload bundle: D1JM1_VxRail-8.0.200-Composite-Upgrade-Slim-Package-for-7.0.x.zip., message= Please refer to KB000062924 article.)ERROR:PartnerUpgradeActionDetail(action=Failed to upload bundle: D1JM1_VxRail-8.0.200-Composite-Upgrade-Slim-Package-for-7.0.x.zip., message=Failed to upload bundle: D1JM1_VxRail-8.0.200-Composite-Upgrade-Slim-Package-for-7.0.x.zip: null. See the KB 000062924 article.)
Cause
第一個原因:
- 在 vCenter 升級的 WLD 網域上發現問題。
- vSphere-UI 服務當機,因為堆積記憶體不足


- 在 /var/log/vmware/vsphere-ui/logs/vsphere-ui-runtime.log.stout 中:
Dumping heap to /var/log/vmware/vsphere-ui/java_pid240884.hprof ... Heap dump file created [968706533 bytes in 3.764 secs] Terminating due to java.lang.OutOfMemoryError: Java heap space
- 使用以下命令檢查 vsphere ui 的堆積記憶體:
cloudvm-ram-size -l

第二期:
- 叢集中第一個節點的磁碟群組遺失
- 由於第一個問題,無法新增磁碟群組
Resolution
- 使用以下命令將堆積記憶體增加到 2500:
cloudvm-ram-size -C 2048 vsphere-ui
- 解決 vCenter 問題後,新增遺失的磁碟群組
- 升級已成功進行
Affected Products
VMWare Cloud on Dell EMC VxRail E560F, VMWare Cloud on Dell EMC VxRail E560N, VxRail Appliance Family, VxRail Appliance Series, VxRail G Series Nodes, VxRail D Series Nodes, VxRail E Series Nodes, VxRail P Series Nodes, VxRail S Series Nodes
, VxRail V Series Nodes
...
Products
VxRail VD Series NodesArticle Properties
Article Number: 000225756
Article Type: Solution
Last Modified: 09 Jul 2024
Version: 2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.