PowerEdge: Mellanox nmlx5 드라이버가 ESXi에서 수많은 L2TableIndex 수정 이벤트를 생성합니다.

Summary: ESXi VMkernel 로그에서 Mellanox nmlx5 드라이버에 의해 생성되는 빈번한 nmlx5_en_L2TableIndexAdd/제거 이벤트 관찰

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

다음 로그 패턴은 ESXi VMkernel에 기록됩니다.
로그 스니펫:
 

2023-11-02T08:55:31.458Z cpu143:2097772)<NMLX_INF> nmlx5_core: vmnic5: nmlx5_en_L2TableIndexRemove - (nmlx5_core_en_main.c:7744) Delete 0:xx:xx:xx:xx:xx from L2 table
2023-11-02T08:55:31.458Z cpu143:2097772)<NMLX_INF> nmlx5_core: vmnic5: nmlx5_en_L2TableIndexAdd - (nmlx5_core_en_main.c:7631) Add 0:xx:xx:xx:x:x to L2 table
2023-11-02T08:55:36.456Z cpu96:2097772)<NMLX_INF> nmlx5_core: vmnic1: nmlx5_en_L2TableIndexRemove - (nmlx5_core_en_main.c:7744) Delete 0:xx:xx:xx:xx:xx from L2 table
2023-11-02T08:55:36.458Z cpu96:2097772)<NMLX_INF> nmlx5_core: vmnic1: nmlx5_en_L2TableIndexAdd - (nmlx5_core_en_main.c:7631) Add 0:xx:xx:xx:xx:xx to L2 table

Cause

예상된 동작입니다. VMkernel의 NetQ 로드 밸런서가 vmnic 대기열을 기반으로 MAC 필터를 추가하려고 할 때마다 이벤트 nmlx5_en_L2TableIndexAdd가 ESXi 로그에 기록됩니다. 마찬가지로 대기열에서 필터가 제거되면 이벤트 nmlx5_en_L2TableIndexRemove가 ESXi 로그에 기록됩니다.
이러한 이벤트는 이러한 필터의 이동이 호스트에 있는 MAC 필터(VM 및 VMK 포함)의 수와 로드 밸런서에서 관리하는 특정 Rx 대기열의 로드에 따라 달라지는 경우에도 생성됩니다.

Resolution

이러한 이벤트는 L2 테이블의 트래픽 필터링 변경 사항에 대해 사용자를 업데이트합니다. 정보 이벤트이므로 기능에는 영향을 주지 않습니다.
 

Affected Products

Mellanox Family of Adapters, VMware ESXi 7.x

Products

PowerEdge XR2, Poweredge C4140, PowerEdge C6420, PowerEdge C6520, PowerEdge C6525, PowerEdge MX740C, PowerEdge MX750c, PowerEdge MX840C, PowerEdge R350, PowerEdge R440, PowerEdge R450, PowerEdge R540, PowerEdge R550, PowerEdge R640, PowerEdge R6415 , PowerEdge R650, PowerEdge R650xs, PowerEdge R6515, PowerEdge R6525, PowerEdge R740, PowerEdge R740XD, PowerEdge R740XD2, PowerEdge R7415, PowerEdge R7425, PowerEdge R750, PowerEdge R750XA, PowerEdge R750xs, PowerEdge R7515, PowerEdge R7525, PowerEdge R840, PowerEdge R940, PowerEdge R940xa, PowerEdge T350, PowerEdge T440, PowerEdge T550, PowerEdge T640, PowerEdge XE2420, PowerEdge XE7420, PowerEdge XE7440, PowerEdge XE8545, PowerEdge XR11, PowerEdge XR12, PowerFlex appliance R650, PowerFlex appliance R6525, Powerflex appliance R750, VMware ESXi 8.x, PowerFlex appliance R640, PowerFlex appliance R740XD, PowerFlex appliance R7525, PowerFlex appliance R840 ...
Article Properties
Article Number: 000225826
Article Type: Solution
Last Modified: 22 Apr 2025
Version:  3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.