PowerScale F 系列节点缺少 mgmt-1 和 mgmt-2 接口
Summary: PowerScale OneFS 命令中不显示 1GbE 接口。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
部署 PowerScale F600、F900、F210 或 F710 节点时,1GbE (mgmt-1/mgmt-2) 接口不会显示在群集配置向导中。将节点添加到现有群集时,在 isi network interfaces 输出中不会显示 mgmt-1 和 mgmt-2 接口。
# isi network interfaces list LNN Name Status VLAN ID Owners Owner Type IP Addresses ----------------------------------------------------------------------------------- 1 25gige-1 Up - - - - 1 25gige-2 No Carrier - - - - -----------------------------------------------------------------------------------
群集上的 ifconfig 输出显示 bge0 和 bge1 接口。
# /sbin/ifconfig -a| grep flags bge0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> metric 0 mtu 1500 bge1: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> metric 0 mtu 1500 lo0: flags=8049<UP,LOOPBACK,RUNNING,MULTICAST> metric 0 mtu 16384 mce0: flags=40008863<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST,ISIINTERNAL> metric 0 mtu 9000 mce1: flags=40008863<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST,ISIINTERNAL> metric 0 mtu 1500 mce2: flags=8863<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> metric 0 mtu 1500 mce3: flags=8863<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> metric 0 mtu 1500 ue0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> metric 0 mtu 1500
Cause
1GbE 接口已从 OneFS 配置中删除。
Resolution
请联系 戴尔技术支持,并引用此知识库文章。
Affected Products
PowerScale F210, PowerScale F600, PowerScale F710, PowerScale F900Products
PowerScale F210Article Properties
Article Number: 000225843
Article Type: Solution
Last Modified: 14 Jan 2025
Version: 6