Connectrix: : SAN Nav: SNMP performance data collection failed for switch Protocol error.

Summary: This issue is seen on the SAN Nav where snmp validation fails and events are generated while trying to manually configure snmp on a switch.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Error Message on SAN Nav:

SAN Nav
 

Cause

This issue is seen when:
  • Switches newly added to fabric and discovered successfully 
  • Switch underwent a Switch FOS upgrade
  • Existing snmp credentials changed and trying to add new snmp credentials

Resolution

1.Perform the below workaround to resolve the issue:

On the departmental model:
#hareboot 
On the Director class model:
#Hafailover 
2. Re-configure manually the snmp credentials

Affected Products

Connectrix SANnav