ISILON:事件通知:NODE_AGGREGATE_LINK_DOWN Smart Connect 环境中。

Summary: 当动态 IP 地址移动时,将引发NODE_AGGREGATE_LINK_DOWN事件。 当节点重新启动或接口发生故障时,动态 IP 地址将移动。 如果手动重新平衡策略,则不会重新平衡动态 IP 地址。 在这种情况下,NODE_AGGREGATE_LINK_DOWN事件会一直存在,直到发出手动重新平衡。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

动态 IP 地址移动的情况。
正常状态
示例如下所示,xxx.xxx.xxx.71 到 74 分配给 groupnet0.subnet_main_service.pool_main_service_dynamic 中的每个节点

# isi network interfaces list
LNN  Name         Status     VLAN ID  Owners                                                  Owner Type  IP Addresses
  ------------------------------------------------------------------------------------------------------------------------
6      10gige-1 Up - - - -
6      10gige-2 Up - - - -
6      10gige-agg-1 Up - - - -
6      10gige-agg-1 Up 310 groupnet0.subnet_main_backup.pool_main_backup Static xxx.xxx.xx.231
6      10gige-agg-1 Up 117 groupnet0.subnet_main_service.pool_main_service_dynamic Dynamic xxx.xxx.xxx.74
            groupnet0.subnet_main_service.pool_main_service_static Static xxx.xxx.xxx.81
6 mgmt-1 No Carrier - - - -
7      10gige-1 Up - - - -
7      10gige-2 Up - - - -
7      10gige-agg-1 Up - - - -
7      10gige-agg-1 Up 310 groupnet0.subnet_main_backup SSIP xxx.xxx.xxx.250
            groupnet0.subnet_main_backup.pool_main_backup Static xxx.xxx.xxx.232
7      10gige-agg-1 Up 117 groupnet0.subnet_main_service.pool_main_service_dynamic Dynamic xxx.xxx.xxx.72
            groupnet0.subnet_main_service.pool_main_service_static Static xxx.xxx.xxx.82
7 mgmt-1 No Carrier - - - -
8      10gige-1 Up - - - -
8      10gige-2 Up - - - -
8      10gige-agg-1 Up - - - -
8      10gige-agg-1 Up 310 groupnet0.subnet_main_backup.pool_main_backup Static xxx.xxx.xxx.233
8      10gige-agg-1 Up 117 groupnet0.subnet_main_service SSIP xxx.xxx.xxx.100
            groupnet0.subnet_main_service.pool_main_service_dynamic Dynamic xxx.xxx.xxx.71
            groupnet0.subnet_main_service.pool_main_service_static Static xxx.xxx.xxx.83
8 mgmt-1 No Carrier - - - -
9      10gige-1 Up - - - -
9      10gige-2 Up - - - -
9      10gige-agg-1 Up - - - -
9      10gige-agg-1 Up 310 groupnet0.subnet_main_backup.pool_main_backup Static xxx.xxx.xxx.234
9      10gige-agg-1 Up 117 groupnet0.subnet_main_service.pool_main_service_dynamic Dynamic xxx.xxx.xxx.73
            groupnet0.subnet_main_service.pool_main_service_static Static xxx.xxx.xxx.84
9 mgmt-1 No Carrier - - - - 

异常状态
的示例节点 6 重新启动以进行维护时。分配给节点的 IP 地址将移至另一个节点。
节点 6 的 IP 地址 xxx.xxx.xxx.74 移至节点 7

# isi network interfaces list
LNN  Name         Status     VLAN ID  Owners                                                  Owner Type  IP Addresses  
------------------------------------------------------------------------------------------------------------------------
6      10gige-1 Up - - - -
6      10gige-2 Up - - - -
6      10gige-agg-1 Up - - - -
6      10gige-agg-1 Up 310 groupnet0.subnet_main_backup.pool_main_backup Static xxx.xxx.xxx.231
6      10gige-agg-1 Up 117 groupnet0.subnet_main_service.pool_main_service_dynamic Dynamic -
            groupnet0.subnet_main_service.pool_main_service_static Static xxx.xxx.xxx.81
6 mgmt-1 No Carrier - - - -
7      10gige-1 Up - - - -
7      10gige-2 Up - - - -
7      10gige-agg-1 Up - - - -
7      10gige-agg-1 Up 310 groupnet0.subnet_main_backup SSIP xxx.xxx.xxx.250
            groupnet0.subnet_main_backup.pool_main_backup Static xxx.xxx.xxx.232
7      10gige-agg-1 Up 117 groupnet0.subnet_main_service.pool_main_service_dynamic Dynamic xxx.xxx.xxx.72 xxx.xxx.xxx.74
            groupnet0.subnet_main_service.pool_main_service_static Static xxx.xxx.xxx.82
7 mgmt-1 No Carrier - - - -
8      10gige-1 Up - - - -
8      10gige-2 Up - - - -
8      10gige-agg-1 Up - - - -
8      10gige-agg-1 Up 310 groupnet0.subnet_main_backup.pool_main_backup Static xxx.xxx.xxx.233
8      10gige-agg-1 Up 117 groupnet0.subnet_main_service SSIP xxx.xxx.xxx.100
            groupnet0.subnet_main_service.pool_main_service_dynamic Dynamic xxx.xxx.xxx.71
            groupnet0.subnet_main_service.pool_main_service_static Static xxx.xxx.xxx.83
8 mgmt-1 No Carrier - - - -
9      10gige-1 Up - - - -
9      10gige-2 Up - - - -
9      10gige-agg-1 Up - - - -
9      10gige-agg-1 Up 310 groupnet0.subnet_main_backup.pool_main_backup Static xxx.xxx.xxx.234
9      10gige-agg-1 Up 117 groupnet0.subnet_main_service.pool_main_service_dynamic Dynamic xxx.xxx.xxx.73
            groupnet0.subnet_main_service.pool_main_service_static Static xxx.xxx.xxx.84
9 mgmt-1 No Carrier - - - -

在此状态下,将生成以下事件,并且节点 6 的琥珀色 LED 亮起。

# isi event list
ID     Started     Ended       Causes Short                     Lnn  Events  Severity   
----------------------------------------------------------------------------------------
xxxxx 05/22 12:02     NODE_AGGREGATE_LINK_DOWN 6 6603 critical

Cause

检查网络池 groupnet0.subnet_main_service.pool_main_service_dynamic
重新平衡策略的此网络池是手动的。

# isi network pools view groupnet0.subnet_main_service.pool_main_service_dynamic

                   ID: groupnet0.subnet_main_service.pool_main_service_dynamic
             Groupnet: groupnet0
               Subnet: subnet_main_service
                 Name: pool_main_service_dynamic
                Rules: -
          Access Zone: zone-main-service
    Allocation Method: dynamic
     Aggregation Mode: lacp
          Description: Default ext-1 pool
      Firewall Policy: default_pools_policy
               Ifaces: 6:10gige-agg-1, 7:10gige-agg-1, 8:10gige-agg-1, 9:10gige-agg-1
            IP Ranges: xxx.xxx.xxx.71-xxx.xxx.xxx.74
     IPv6 Perform DAD: No
     Rebalance Policy: manual
   SC Failover Policy: conn_count
        Static Routes: xxx.xxx.xxx.0/24-xxx.xxx.xxx.252
NFSv3 RDMA RRoCE only: No

SmartConnect DNS Settings:
 SC Suspended Nodes: -
  SC Connect Policy: round_robin
            SC Zone: xxxxx.xxxxx.xx.xx
SC DNS Zone Aliases: -
          SC Subnet: subnet_main_service
             SC TTL: 0

Resolution

发出“isi network sc-rebalance-all”命令。

提醒:此命令为 OneFS9.1。检查每个版本的 OneFS CLI 命令参考的重新平衡命令

动态 IP 地址移至没有 IP 地址的接口。发出“isi network interfaces list”命令。检查动态 IP 地址还原。发出“isi event list”命令。检查“NODE_AGGREGATE_LINK_DOWN”是否已解决。如果问题仍然存在,请联系技术支持。

注意:请勿发出 isi event modify --id=“EVENTID” --ignore=true

忽略选项将永久清除。
即使问题未解决,也不会重新创建事件。
解决选项在问题未解决时重新创建事件。

Additional Information

Affected Products

Isilon, PowerScale, Isilon Gen6.5, Isilon Gen6, Isilon NL-Series, PowerScale OneFS, Isilon S-Series, Isilon SmartConnect, Isilon X-Series
Article Properties
Article Number: 000242347
Article Type: Solution
Last Modified: 18 Dec 2024
Version:  6
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.