NVP vProxy: VM-sikkerhetskopiering på VMC vCenter mislykkes etter oppgradering til 4.4.0-4 "Aktiver vMotion for lagring mislyktes. Feil 3014"
Summary: VMware Cloud (VMC) vCenter-sikkerhetskopieringer mislykkes etter at NetWorker-versjonen ble oppgradert til 19.11.0.2 Bygg: 55 og proxy-oppgradering til 4.4.0-4
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Sikkerhetskopiering av image mislyktes med feil etter vProxy-oppgradering til 4.4.0-4 på VMware Cloud (VMC) vCenter.
VM-øktloggen for sikkerhetskopiering inkluderer:
YYYY-MM-DDTHH:MM:SSZ NOTICE: VDDK INFO VixDiskLib: VixDiskLib_EndAccess: Enabled Storage VMotion failed. Error 3014 (Insufficient permissions in the host operating system) (No permission to perform this action.) at 6102. ... YYYY-MM-DDTHH:MM:SSZ ERROR: [@(#) Build number: 55] c0a8f9d0-2604-4747-b4b8-588a4bbfe205-vcenter.sddc-54-247-108-146.VCENTER_NAME:VM_MOREF: Failed to open source VMDK '[DATASTORE_NAME] 3c8e5a63-4e85-2046-0477-026956739693/VM_NAME.vmdk': VDDK Error: 13: You do not have access rights to this file. YYYY-MM-DDTHH:MM:SSZ ERROR: [@(#) Build number: 55] c0a8f9d0-2604-4747-b4b8-588a4bbfe205-vcenter.sddc-54-247-108-146.VCENTER_NAME:VM_MOREF: Failed to initialize Block Reader. YYYY-MM-DDTHH:MM:SSZ ERROR: [@(#) Build number: 55] c0a8f9d0-2604-4747-b4b8-588a4bbfe205-vcenter.sddc-54-247-108-146.VCENTER_NAME:VM_MOREF: Failed to backup virtual disk "Hard disk 1". YYYY-MM-DDTHH:MM:SSZ ERROR: [@(#) Build number: 55] c0a8f9d0-2604-4747-b4b8-588a4bbfe205-vcenter.sddc-54-247-108-146.VCENTER_NAME:VM_MOREF: Backup has FAILED.
vProxys /opt/emc/vproxy/runtime/logs/vbackupd/vbackupd-vddk.log inkluderer:
YYYY-MM-DDTHH:MM:SSZ NOTICE: VDDK INFO VixDiskLib: VixDiskLib_OpenEx: Open a disk. YYYY-MM-DDTHH:MM:SSZ NOTICE: VDDK INFO warning -[19943] [Originator@6876 sub=Libs] [NFC ERROR]NfcNewAuthdConnectionEx: Failed to connect: Failed to connect to server <ESXi hostname/IP>:902 .. YYYY-MM-DDTHH:MM:SSZ NOTICE: VDDK INFO VixDiskLib: There is no avaiable transport mode when attempting to open disk. Mounting 42197eae-c679-dd06-8bbb-418e49607575 using transport hotadd failed : Could not connect to ESX host <ESXi hostname/IP>: Failed to connect to server <ESXi hostname/IP>:902. at 6502. YYYY-MM-DDTHH:MM:SSZ NOTICE: VDDK INFO VixDiskLib: VixDiskLib_OpenEx: Cannot open disk [Datastore-name] <VM-name>/<VMDK_name>.vmdk. Error 13 (You do not have access rights to this file) (Mounting 42197eae-c679-dd06-8bbb-418e49607575 using transport hotadd failed : Could not connect to ESX host <ESXi hostname/IP>: Failed to connect to server <ESXi hostname/IP>:902.) at 7072.
Cause
Den følgende vProxy-konfigurasjonsfilen (/opt/emc/vproxy/conf/VixDiskLib.config) inneholdt dupliserte oppføringer.
VPROXY_HOSTNAME:/opt/emc/vproxy/runtime/logs/vbackupd # cat /opt/emc/vproxy/conf/VixDiskLib.config
vixDiskLib.transport.LogLevel = "3"
vixDiskLib.transport.san.DisableVmCheck=0
vixDiskLib.transport.hotadd.NoNfcSession = 1
vixDiskLib.phoneHome.EnablePhoneHome = 1
vixDiskLib.phoneHome.ProductName = "Dell EMC vProxy"
vixDiskLib.phoneHome.ProductVersion = "4.4.0-4_1-1"
vixDiskLib.phoneHome.EnablePhoneHome = 1
vixDiskLib.phoneHome.ProductName = "Dell EMC vProxy"
vixDiskLib.phoneHome.ProductVersion = "4.4.0-4_1-1"
vixDiskLib.phoneHome.EnablePhoneHome = 1
vixDiskLib.phoneHome.ProductName = "Dell EMC vProxy"
vixDiskLib.phoneHome.ProductVersion = "4.4.0-4_1-1"
vixDiskLib.phoneHome.EnablePhoneHome = 1
vixDiskLib.phoneHome.ProductName = "Dell EMC vProxy"
vixDiskLib.phoneHome.ProductVersion = "4.4.0-4_1-1"
VPROXY_HOSTNAME:/opt/emc/vproxy/runtime/logs/vbackupd # Resolution
1. Koble til vProxy-apparatet via SSH, og logg på som administrator.
2. Bytt til rot:
sudo su -
3. Rediger VixDiskLib.config-filen slik at den ikke har dupliserte vixDiskLib.phoneHome-linjer:
vi /opt/emc/vproxy/conf/VixDiskLib.config
Eksempel:
vixDiskLib.transport.LogLevel = "3" vixDiskLib.transport.san.DisableVmCheck=0 vixDiskLib.transport.hotadd.NoNfcSession = 1 vixDiskLib.phoneHome.EnablePhoneHome = 1 vixDiskLib.phoneHome.ProductName = "Dell EMC vProxy" vixDiskLib.phoneHome.ProductVersion = "4.4.0-4_1-1"4. Lagre filen.
5. Start vbackupd-tjenesten på nytt.
systemctl daemon-reload systemctl restart vbackupd.service
MERK: I stedet for å starte tjenestene på nytt, kan vProxy VM eventuelt startes på nytt. Omstart av vProxy VM laster inn endringene i VixDiskLib.config-filen på nytt under oppstart av vbackupd service.
Affected Products
NetWorkerProducts
NetWorker FamilyArticle Properties
Article Number: 000255608
Article Type: Solution
Last Modified: 09 Dec 2024
Version: 2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.