NVP vProxy: Os backups de VM no VMC vCenter falham após o upgrade para a versão 4.4.0-4. "Falha ao ativar o vMotion de armazenamento. Erro 3014"
Summary: Falha nos backups de imagem do VMware Cloud (VMC) vCenter após o upgrade da versão do NetWorker para a versão 19.11.0.2 Compilação: 55 e upgrade de proxy para 4.4.0-4
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Os backups de imagem estavam falhando com erro após o upgrade do vProxy para a versão 4.4.0-4 no VMware Cloud (VMC) vCenter.
O log da sessão de backup da VM inclui:
YYYY-MM-DDTHH:MM:SSZ NOTICE: VDDK INFO VixDiskLib: VixDiskLib_EndAccess: Enabled Storage VMotion failed. Error 3014 (Insufficient permissions in the host operating system) (No permission to perform this action.) at 6102. ... YYYY-MM-DDTHH:MM:SSZ ERROR: [@(#) Build number: 55] c0a8f9d0-2604-4747-b4b8-588a4bbfe205-vcenter.sddc-54-247-108-146.VCENTER_NAME:VM_MOREF: Failed to open source VMDK '[DATASTORE_NAME] 3c8e5a63-4e85-2046-0477-026956739693/VM_NAME.vmdk': VDDK Error: 13: You do not have access rights to this file. YYYY-MM-DDTHH:MM:SSZ ERROR: [@(#) Build number: 55] c0a8f9d0-2604-4747-b4b8-588a4bbfe205-vcenter.sddc-54-247-108-146.VCENTER_NAME:VM_MOREF: Failed to initialize Block Reader. YYYY-MM-DDTHH:MM:SSZ ERROR: [@(#) Build number: 55] c0a8f9d0-2604-4747-b4b8-588a4bbfe205-vcenter.sddc-54-247-108-146.VCENTER_NAME:VM_MOREF: Failed to backup virtual disk "Hard disk 1". YYYY-MM-DDTHH:MM:SSZ ERROR: [@(#) Build number: 55] c0a8f9d0-2604-4747-b4b8-588a4bbfe205-vcenter.sddc-54-247-108-146.VCENTER_NAME:VM_MOREF: Backup has FAILED.
O /opt/emc/vproxy/runtime/logs/vbackupd/vbackupd-vddk.log do vProxy inclui:
YYYY-MM-DDTHH:MM:SSZ NOTICE: VDDK INFO VixDiskLib: VixDiskLib_OpenEx: Open a disk. YYYY-MM-DDTHH:MM:SSZ NOTICE: VDDK INFO warning -[19943] [Originator@6876 sub=Libs] [NFC ERROR]NfcNewAuthdConnectionEx: Failed to connect: Failed to connect to server <ESXi hostname/IP>:902 .. YYYY-MM-DDTHH:MM:SSZ NOTICE: VDDK INFO VixDiskLib: There is no avaiable transport mode when attempting to open disk. Mounting 42197eae-c679-dd06-8bbb-418e49607575 using transport hotadd failed : Could not connect to ESX host <ESXi hostname/IP>: Failed to connect to server <ESXi hostname/IP>:902. at 6502. YYYY-MM-DDTHH:MM:SSZ NOTICE: VDDK INFO VixDiskLib: VixDiskLib_OpenEx: Cannot open disk [Datastore-name] <VM-name>/<VMDK_name>.vmdk. Error 13 (You do not have access rights to this file) (Mounting 42197eae-c679-dd06-8bbb-418e49607575 using transport hotadd failed : Could not connect to ESX host <ESXi hostname/IP>: Failed to connect to server <ESXi hostname/IP>:902.) at 7072.
Cause
O seguinte arquivo de configuração do vProxy (/opt/emc/vproxy/conf/VixDiskLib.config) continha entradas duplicadas.
VPROXY_HOSTNAME:/opt/emc/vproxy/runtime/logs/vbackupd # cat /opt/emc/vproxy/conf/VixDiskLib.config
vixDiskLib.transport.LogLevel = "3"
vixDiskLib.transport.san.DisableVmCheck=0
vixDiskLib.transport.hotadd.NoNfcSession = 1
vixDiskLib.phoneHome.EnablePhoneHome = 1
vixDiskLib.phoneHome.ProductName = "Dell EMC vProxy"
vixDiskLib.phoneHome.ProductVersion = "4.4.0-4_1-1"
vixDiskLib.phoneHome.EnablePhoneHome = 1
vixDiskLib.phoneHome.ProductName = "Dell EMC vProxy"
vixDiskLib.phoneHome.ProductVersion = "4.4.0-4_1-1"
vixDiskLib.phoneHome.EnablePhoneHome = 1
vixDiskLib.phoneHome.ProductName = "Dell EMC vProxy"
vixDiskLib.phoneHome.ProductVersion = "4.4.0-4_1-1"
vixDiskLib.phoneHome.EnablePhoneHome = 1
vixDiskLib.phoneHome.ProductName = "Dell EMC vProxy"
vixDiskLib.phoneHome.ProductVersion = "4.4.0-4_1-1"
VPROXY_HOSTNAME:/opt/emc/vproxy/runtime/logs/vbackupd # Resolution
1. Conecte-se ao equipamento vProxy via SSH e faça log-in como administrador.
2. Alterne para root:
sudo su -
3. Edite o arquivo VixDiskLib.config para que ele não tenha linhas vixDiskLib.phoneHome duplicadas:
vi /opt/emc/vproxy/conf/VixDiskLib.config
Exemplo:
vixDiskLib.transport.LogLevel = "3" vixDiskLib.transport.san.DisableVmCheck=0 vixDiskLib.transport.hotadd.NoNfcSession = 1 vixDiskLib.phoneHome.EnablePhoneHome = 1 vixDiskLib.phoneHome.ProductName = "Dell EMC vProxy" vixDiskLib.phoneHome.ProductVersion = "4.4.0-4_1-1"4. Salve o arquivo.
5. Reinicie o serviço vbackupd.
systemctl daemon-reload systemctl restart vbackupd.service
Nota: Opcionalmente, em vez de reiniciar os serviços, a VM do vProxy pode ser reinicializada. A reinicialização da VM do vProxy recarrega as alterações no arquivo VixDiskLib.config durante a inicialização do serviço vbackupd.