NVP vProxy:升级到 4.4.0-4 后,VMC vCenter 上的虚拟机备份失败,“Enable Storage vMotion failed.错误 3014”

Summary: NetWorker 版本升级到 19.11.0.2 后,VMware Cloud (VMC) vCenter 映像备份失败 内部版本:55 和代理升级到 4.4.0-4

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

在 VMware Cloud (VMC) vCenter 上将 vProxy 升级到 4.4.0-4 后,映像备份失败并显示错误。
虚拟机备份会话日志包括:

YYYY-MM-DDTHH:MM:SSZ NOTICE: VDDK INFO VixDiskLib: VixDiskLib_EndAccess: Enabled Storage VMotion failed. Error 3014 (Insufficient permissions in the host operating system) (No permission to perform this action.) at 6102.
...
YYYY-MM-DDTHH:MM:SSZ ERROR:  [@(#) Build number: 55] c0a8f9d0-2604-4747-b4b8-588a4bbfe205-vcenter.sddc-54-247-108-146.VCENTER_NAME:VM_MOREF: Failed to open source VMDK '[DATASTORE_NAME] 3c8e5a63-4e85-2046-0477-026956739693/VM_NAME.vmdk': VDDK Error: 13: You do not have access rights to this file.
YYYY-MM-DDTHH:MM:SSZ ERROR:  [@(#) Build number: 55] c0a8f9d0-2604-4747-b4b8-588a4bbfe205-vcenter.sddc-54-247-108-146.VCENTER_NAME:VM_MOREF: Failed to initialize Block Reader.
YYYY-MM-DDTHH:MM:SSZ ERROR:  [@(#) Build number: 55] c0a8f9d0-2604-4747-b4b8-588a4bbfe205-vcenter.sddc-54-247-108-146.VCENTER_NAME:VM_MOREF: Failed to backup virtual disk "Hard disk 1".
YYYY-MM-DDTHH:MM:SSZ ERROR:  [@(#) Build number: 55] c0a8f9d0-2604-4747-b4b8-588a4bbfe205-vcenter.sddc-54-247-108-146.VCENTER_NAME:VM_MOREF: Backup has FAILED.

vProxy 的 /opt/emc/vproxy/runtime/logs/vbackupd/vbackupd-vddk.log包括:

YYYY-MM-DDTHH:MM:SSZ NOTICE: VDDK INFO VixDiskLib: VixDiskLib_OpenEx: Open a disk.
YYYY-MM-DDTHH:MM:SSZ NOTICE: VDDK INFO warning -[19943] [Originator@6876 sub=Libs] [NFC ERROR]NfcNewAuthdConnectionEx: Failed to connect: Failed to connect to server <ESXi hostname/IP>:902
..
YYYY-MM-DDTHH:MM:SSZ NOTICE: VDDK INFO VixDiskLib: There is no avaiable transport mode when attempting to open disk. Mounting 42197eae-c679-dd06-8bbb-418e49607575 using transport hotadd failed : Could not connect to ESX host <ESXi hostname/IP>: Failed to connect to server <ESXi hostname/IP>:902. at 6502.
YYYY-MM-DDTHH:MM:SSZ NOTICE: VDDK INFO VixDiskLib: VixDiskLib_OpenEx: Cannot open disk [Datastore-name] <VM-name>/<VMDK_name>.vmdk. Error 13 (You do not have access rights to this file) (Mounting 42197eae-c679-dd06-8bbb-418e49607575 using transport hotadd failed : Could not connect to ESX host <ESXi hostname/IP>: Failed to connect to server <ESXi hostname/IP>:902.) at 7072.

    Cause

    以下 vProxy 配置文件 (/opt/emc/vproxy/conf/VixDiskLib.config) 包含重复的条目。

    VPROXY_HOSTNAME:/opt/emc/vproxy/runtime/logs/vbackupd # cat /opt/emc/vproxy/conf/VixDiskLib.config
    vixDiskLib.transport.LogLevel = "3"
    vixDiskLib.transport.san.DisableVmCheck=0
    vixDiskLib.transport.hotadd.NoNfcSession = 1
    vixDiskLib.phoneHome.EnablePhoneHome = 1
    vixDiskLib.phoneHome.ProductName = "Dell EMC vProxy"
    vixDiskLib.phoneHome.ProductVersion = "4.4.0-4_1-1"
    vixDiskLib.phoneHome.EnablePhoneHome = 1
    vixDiskLib.phoneHome.ProductName = "Dell EMC vProxy"
    vixDiskLib.phoneHome.ProductVersion = "4.4.0-4_1-1"
    vixDiskLib.phoneHome.EnablePhoneHome = 1
    vixDiskLib.phoneHome.ProductName = "Dell EMC vProxy"
    vixDiskLib.phoneHome.ProductVersion = "4.4.0-4_1-1"
    vixDiskLib.phoneHome.EnablePhoneHome = 1
    vixDiskLib.phoneHome.ProductName = "Dell EMC vProxy"
    vixDiskLib.phoneHome.ProductVersion = "4.4.0-4_1-1"
    VPROXY_HOSTNAME:/opt/emc/vproxy/runtime/logs/vbackupd # 

    Resolution

    1.通过 SSH 连接到 vProxy 设备,以管理员身份登录。
    2.切换到 root:

    sudo su -

    3.编辑 VixDiskLib.config 文件,使其不具有重复的 vixDiskLib.phoneHome 行:

    vi /opt/emc/vproxy/conf/VixDiskLib.config
    示例:
    vixDiskLib.transport.LogLevel = "3"
    vixDiskLib.transport.san.DisableVmCheck=0
    vixDiskLib.transport.hotadd.NoNfcSession = 1
    vixDiskLib.phoneHome.EnablePhoneHome = 1
    vixDiskLib.phoneHome.ProductName = "Dell EMC vProxy"
    vixDiskLib.phoneHome.ProductVersion = "4.4.0-4_1-1"
    4.保存文件。
    5.重新启动 vbackupd 服务。
    systemctl daemon-reload
    systemctl restart vbackupd.service
    提醒:(可选)可以重新启动 vProxy 虚拟机,而不是重新启动服务。重新启动 vProxy 虚拟机会在 vbackupd 服务启动期间重新加载 VixDiskLib.config 文件中的更改。

    Affected Products

    NetWorker

    Products

    NetWorker Family
    Article Properties
    Article Number: 000255608
    Article Type: Solution
    Last Modified: 09 Dec 2024
    Version:  2
    Find answers to your questions from other Dell users
    Support Services
    Check if your device is covered by Support Services.