PowerScale:尋找哪個磁碟機屬於哪個磁碟集區
Summary: 磁碟池是分佈在群集節點子集之間的磁碟集合。它是叢集儲存基礎結構的一部分,可協助管理資料在多個磁碟上的儲存方式。磁碟集區背後的概念是最佳化效能、可靠性和儲存效率。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Instructions
若要尋找哪個磁碟機屬於磁碟集區,請使用 disi -I diskpools ls 命令,以列出磁碟池及其成員。檢查「成員」欄,以識別磁碟集區 ID 和對應的托架號碼。
症狀:
兩個磁碟機處於 SmartFail 狀態。
- 磁碟機 – 托架 C1
- 磁碟機 – 托架 C2
# isi devices drive list Lnn Location Device Lnum State Serial Sled ----------------------------------------------------------- 4 Bay 1 /dev/da1 15 L3 GKNX0K100651 N/A -1 4 Bay 2 - N/A EMPTY N/A -2 4 Bay A0 /dev/da9 9 HEALTHY K7H0R3KL A -3 4 Bay A1 /dev/da2 14 HEALTHY K7H0MAHL A -4 4 Bay A2 /dev/da10 8 HEALTHY K7GS3V5L A -5 4 Bay B0 /dev/da3 13 HEALTHY K7H11MJL B -6 4 Bay B1 /dev/da11 7 HEALTHY K7H0918L B -7 4 Bay B2 /dev/da4 12 HEALTHY K7H0Y0TL B -8 4 Bay C0 /dev/da13 17 HEALTHY V30SNMWM C -9 4 Bay C1 /dev/da12 11 SMARTFAIL K7GYYE9L C -10 <<<<<< 4 Bay C2 /dev/da5 5 SMARTFAIL K7H0R0HL C -11 <<<<<< 4 Bay D0 /dev/da6 10 HEALTHY K7GZMATL D -12 4 Bay D1 /dev/da14 4 HEALTHY K7H0Y8VL D --13 4 Bay D2 /dev/da7 3 HEALTHY K4KDWD6B D --14 4 Bay E0 /dev/da15 2 HEALTHY K4KDWG5B E --15 4 Bay E1 /dev/da8 1 HEALTHY K4KDYTWB E --16 4 Bay E2 /dev/da16 0 HEALTHY K7H0R8ZL E --17 ----------------------------------------------------------- Total: 17
Cause:
SmartFailed 磁碟機屬於磁碟集區 3 和 4 的外框 C1 和外框 C2。
- 磁碟機在命令輸出結果中列為 SMARTFAIL。
`isi storage pool list`。 - 磁碟機會根據
disi -I diskpools ls命令。
Exampledisi -I diskpools lsoutput:Name Id Type Prot Flags Members VHS HDD Used / Size SSD Used / Size ------------------------------------------------------------------------------------------------------------------------- h40_60tb_3.2tb-ssd_128gb 1 G +2d: SDH---I-- 2-4 1 196T / 201T (97% ) 0 / 0 (n/a ) 1n h40_60tb_3.2tb- 2 D +2d: S-----IG- 1-4:bay3,6,9,12,15 - 66T / 69T (95% ) 0 / 0 (n/a ) ssd_128gb:2 1n h40_60tb_3.2tb- 3 D +2d: S-----IG- 1-4:bay4,7,10,13,16 - 65T / 66T (99% ) 0 / 0 (n/a ) ssd_128gb:3 1n h40_60tb_3.2tb- 4 D +2d: S-----IG- 1-4:bay5,8,11,14,17 - 65T / 66T (98% ) 0 / 0 (n/a ) ssd_128gb:4 1n ------------------------------------------------------------------------------------------------------------------------- Unprovisioned drives: none Draining drives: none Type: D = Disk pool, G = Group, P = Policy, T = Tier, E = Empty Group or Tier Flags: S = System, H = VHS Hide Spare, D = VHS Deny Writes, T = Spillover Target, M = Manual Group, E = Evacuate Pool, I = Force 8k inodes, R = Data Reduce, G = Gna Disabled
從上述輸出中,磁碟集區 3 和 4 列示如下:
h40_60tb_3.2tb- 3 D +2d: S-----IG- 1-4:bay4,7,10,13,16 - 65T / 66T (99% ) 0 / 0 (n/a ) ssd_128gb:3 1n h40_60tb_3.2tb- 4 D +2d: S-----IG- 1-4:bay5,8,11,14,17 - 65T / 66T (98% ) 0 / 0 (n/a ) ssd_128gb:4 1n
解決方案:
若要尋找外框上的哪個磁碟機屬於磁碟集區,請按照下列步驟操作:
- 執行
`disi -I diskpools命令,以列出所有磁碟池。 - 尋找包含您要檢查之磁碟機的磁碟機槽編號的磁碟集區。
- 例如,若要檢查磁碟機槽 C1,請尋找包含磁碟機槽編號 4、7、10、13 和 16 的磁碟集區。
- 檢查磁碟池 ID 和名稱,並記下與其相關聯的凹槽編號。
disi -I diskpools ls
在輸出中,智慧故障磁碟機屬於磁碟集區 3 和 4 的外框 10 和外框 11。
h40_60tb_3.2tb- 3 D +2d: S-----IG- 1-4:bay4,7,10,13,16 - 65T / 66T (99% ) 0 / 0 (n/a ) ssd_128gb:3 1n h40_60tb_3.2tb- 4 D +2d: S-----IG- 1-4:bay5,8,11,14,17 - 65T / 66T (98% ) 0 / 0 (n/a ) ssd_128gb:4 1n
因此,磁碟機槽 C1 和磁碟機槽 C2 中的磁碟機屬於磁碟集區 3 和 4。