PPDM: Implementering af vSphere-installationspakken mislykkes med fejlkoden "ABV0032"

Summary: På Broadcom ESXi-værten mislykkes implementering eller opdatering af vSphere Installation Bundle (VIB) med fejlkode ABV0032.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Under implementering eller opdatering af PowerProtect Data Manager (PPDM) vSphere-installationspakke til TSDM (Transparent Snapshot Data Mover) mislykkes konfigurationsjobbet med fejlmeddelelser i stil med følgende:

ABV0032: VM Direct Engine is unable to configure protection for the host "ESXi Host" on vCenter "VCenterName"

 

Under afsnittet med oplysninger om fejl rapporteres en fejlmeddelelse i stil med følgende:

Unable to install vSphere Installation Bundle on host "ESXi Host". vCenter task is failed with /usr/sbin/esxupdate returned with exit status: 15
 

 

Jobfejl i PPDM-brugergrænsefladen

 

Cause

Lagerscanning er påkrævet på en vCenter-server. Uden dette rapporteres fejlmeddelelser i stil med følgende i logfilen "esxupdate" på Broadcom ESXi-værten:

 

esxupdate: 9408626: Transaction: INFO: Final list of VIBs being installed: DEL_bootbank_tsdm_19. 18. 0. 3-10EM. 703. 0.0.18644231
esxupdate: 9408626: imageprofile: INFO: Adding VIB DEL_bootbank_tsdm_19. 18.0.3-10EM. 703. 0.0.18644231 to ImageProfile (Updated) ESXi-7. OU3n-21930508-standard
esxupdate: 9408626: esxupdate: ERROR: An esxupdate error exception was caught:
esxupdate: 9408626: esxupdate: ERROR: Traceback (most recent call last) :
File "/lib64/python3.8/site-packages/vmware/esximage/Utils/HostInfo.py", line 217, in getFileSystems
return runCli ( ['storage', 'filesystem', 'list' ], True)
File "/lib64/python3.8/site-packages/esxutils.py", line 220, in runCli
esxupdate: 9408626: esxupdate: ERROR: esxutils. EsxcliError: Errors:
esxupdate: 9408626: esxupdate: ERROR: Error getting data for filesystem on '/vmfs/volumes/xxxxxxxx-xxxxxxxx-xxxx-xxxxxxxxxxx': Cannot open volume: /vmfs/volumes/xxxxxxxx-xxxxxxxx-xxxx-xxxxxxxxxxx, skipping.
esxupdate: 9408626: esxupdate: ERROR:
ERROR:
esxupdate: 9408626: esxupdate:
esxupdate: 9408626: esxupdate: ERROR: During handling of the above exception, another exception occurred:
esxupdate: 9408626: esxupdate: ERROR:
esxupdate: 9408626: esxupdate: ERROR: Traceback (most recent call last) :
File "/usr/sbin/esxupdate", line 222, in main
cmd. Run ()
File "/lib64/python3.8/site-packages/vmware/esx5update/Cmdline.py", line 153, in Run
File "/lib64/python3.8/site-packages/vmware/esximage/Transaction.py", line 852, in InstallVibsFromSources
inst, removed, exitstate = self. installVibs (curprofile,
File "/lib64/python3.8/site-packages/vmware/esximage/Transaction.py", line 1098, in installVibs
exitstate = self. validateAndInstallProfile(
File "/lib64/python3.8/site-packages/vmware/esximage/Transaction.py", line 1267, in validateAndInstallProfile
resVibCache = ReservedVibCache ()
File "/lib64/python3.8/site-packages/vmware/esximage/ImageManager/HostSeeding.py", line 995, in init
self. loadCachedVibs ()
File "/lib64/python3.8/site-packages/vmware/esximage/ImageManager/HostSeeding.py", line 1032, in loadCachedVibs
for fsPath in HostInfo.GetVmfslFileSystems () :
File "/lib64/python3. 8/site-packages/vmware/esximage/Utils/HostInfo.py", line 260, in GetVmfslFileSystems
return [fs['Mount Point'] for fs in getFileSystems ()
File "/lib64/python3.8/site-packages/vmware/esximage/Utils/HostInfo.py", line 220, in getFileSystems
raise Errors. InstallationError (e, None, msg)
esxupdate: 9408626: esxupdate: ERROR: vmware. esximage. Errors. InstallationError: Failed to query file system stats: Errors:
esxupdate: 9408626: esxupdate: ERROR: Error getting data for filesystem on '/vmfs/volumes/xxxxxxxx-xxxxxxxx-xxxx-xxxxxxxxxxx': Cannot open volume: /vmfs/volumes/xxxxxxxx-xxxxxxxx-xxxx-xxxxxxxxxxx, skipping.
esxupdate: 9408626: esxupdate: ERROR:
esxupdate: 9408626: esxupdate: DEBUG: <<<

Resolution

For at løse dette problem er det nødvendigt at scanne storageenheder igen.

 

Følgende Knowledge Base-artikel fra Broadcom indeholder instruktioner om, hvordan du udfører genscanning af storage [Eksternt link sidst kontrolleret den 11. marts 2025]:

 Udførelse af en ny scanning af storage på en ESXi-vært 

 

Affected Products

PowerProtect Data Manager, PowerProtect Data Manager Essentials