Zařízení PowerFlex se nepřidá do fondu úložišť
Summary: Zařízení nebude přidáno do fondu úložiště kvůli chybám I/O.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Operace přidání zařízení se nezdařila kvůli chybám IO.
Přidání se nezdařilo se zobrazit v protokolech MDM následujícím způsobem:
2017-07-07 09:57:20.178 OPEN_SDS_DEVICE_FAILED ERROR Could not open a device on SDS: 473a915e00000009 (Path: /dev/mapper/svm_sdz). Error message: Add SDS device IO error 2017-07-07 09:55:42.916 OPEN_SDS_DEVICE_FAILED ERROR Could not open a device on SDS: 473a915e00000009 (Path: /dev/mapper/svm_sdz). Error message: Add SDS device IO error 2017-07-07 09:55:42.921 CLI_COMMAND_FAILED WARNING Command add_sds_device was not successful. Error code: Add SDS device IO error [19087506] ID: 0000000000000000 2017-07-07 09:57:15.457 MDM_CLI_CONF_COMMAND_RECEIVED INFO Command add_sds_device received, User: ''. [19090058] SDS: Name: SDS05, SDS Device:name SDS05-SVM_SDZ path /dev/mapper/svm_sdz, Storage Pool: ENCPOOL1, Test Mode: 'Test and activate' Test Time: 0 force_device_takeover flag: Omitted 2017-07-07 09:57:20.175 SDS_DEV_ERROR_REPORT ERROR Device error reported on SDS: SDS05, Device: /dev/mapper/svm_sdz. State: NORMAL upDownState: UP processState: DEV_ERR_INPROGRESS
Důsledky
Nelze přidat zařízení, snížená kapacita.
Cause
Funkce SDS Trace zobrazuje selhání operace přidání zařízení s chybami IO kvůli nereagujícímu/pomalému disku:
07/07 09:57:19.011555 0x7fd5438ffeb0:mosAsyncIO_DoIOTimedSyncIntern:01336: Time budget exceeded during IO to /dev/mapper/svm_sdz (Give-up on inflight IO) 07/07 09:57:19.011569 0x7fd5438ffeb0:mosAsyncIO_WriteZeroTimedSync:00811: mosAsyncIO_DoIOTimedSync returned ERROR, offset = 55574528, writeSize = 1048576 07/07 09:57:20.011293 0x7fd5438ffeb0:mosAsyncIO_DoIOTimedSyncIntern:01336: Time budget exceeded during IO to /dev/mapper/svm_sdz (Give-up on inflight IO) 07/07 09:57:20.011300 0x7fd5438ffeb0:mosAsyncIO_WriteZeroTimedSync:00811: mosAsyncIO_DoIOTimedSync returned ERROR, offset = 0, writeSize = 1048576 07/07 09:57:20.011304 0x7fd5438ffeb0:contDev_SendDeviceError:01632: Sending device error to MDM: DevId:97dfea7500090017 deviceName: /dev/mapper/svm_sdz readError: FALSE WriteError: TRUE 07/07 09:57:20.011471 0x7fd5438ffeb0:phyDev_InitWithBuf:02152: Io error /dev/mapper/svm_sdz, size 409600 07/07 09:57:20.011482 0x7fd5438ffeb0:contDev_SendDeviceError:01632: Sending device error to MDM: DevId:97dfea7500090017 deviceName: /dev/mapper/svm_sdz readError: TRUE WriteError: TRUE 07/07 09:57:20.015684 0x7fd5438ffeb0:contCmd_RemDevIntern:01022: DevId 97dfea7500090017 - Start rc = SUCCESS 07/07 09:57:20.015703 0x7fd5438ffeb0:contCmd_AddDev:01401: DevId 97dfea7500090017 - Done rc = TGT_ADD_DEV_IO_ERROR
/var/log/message ukázaly, že ovladač HBA má problémy s diskem, přerušením a vypršením časového limitu:
Jul 7 09:57:15 scaleio05 kernel: mpt3sas_cm0: log_info(0x31120303): originator(PL), code(0x12), sub_code(0x0303) Jul 7 09:57:15 scaleio05 kernel: mpt3sas_cm0: log_info(0x3112010c): originator(PL), code(0x12), sub_code(0x010c)
Resolution
Po výměně vadného HW projděte všechny disky (včetně root drive: satadom):
- Vynulujte první MB disku
- Restartujte proces SDS v SVM
- Ověření, že disk funguje bez chyb a zašifruje se v CloudLink.
- Přidat do fondu úložišť