Das PowerFlex-Gerät wird nicht zum Storage-Pool hinzugefügt.

Summary: Das Gerät wird aufgrund von I/O-Fehlern nicht zum Storage-Pool hinzugefügt.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Der Vorgang zum Hinzufügen des Geräts ist aufgrund von IO-Fehlern fehlgeschlagen.

Das fehlgeschlagene Hinzufügen wurde in den MDM-Protokollen wie folgt angezeigt:

2017-07-07 09:57:20.178 OPEN_SDS_DEVICE_FAILED    ERROR            Could not open a device on SDS: 473a915e00000009 (Path: /dev/mapper/svm_sdz). Error message: Add SDS device IO error
2017-07-07 09:55:42.916 OPEN_SDS_DEVICE_FAILED    ERROR            Could not open a device on SDS: 473a915e00000009 (Path: /dev/mapper/svm_sdz). Error message: Add SDS device IO error
2017-07-07 09:55:42.921 CLI_COMMAND_FAILED        WARNING          Command add_sds_device was not successful. Error code: Add SDS device IO error [19087506] ID: 0000000000000000
2017-07-07 09:57:15.457 MDM_CLI_CONF_COMMAND_RECEIVED INFO         Command add_sds_device received, User: ''. [19090058] SDS: Name: SDS05, SDS Device:name SDS05-SVM_SDZ path /dev/mapper/svm_sdz, Storage Pool: ENCPOOL1, Test Mode: 'Test and activate' Test Time: 0 force_device_takeover flag: Omitted
2017-07-07 09:57:20.175 SDS_DEV_ERROR_REPORT      ERROR            Device error reported on SDS: SDS05, Device: /dev/mapper/svm_sdz. State: NORMAL upDownState: UP processState: DEV_ERR_INPROGRESS 

 

Auswirkungen 

Ein Gerät kann nicht hinzugefügt werden, reduzierte Kapazität.

Cause

Die SDS-Ablaufverfolgung zeigt, dass der Vorgang zum Hinzufügen eines Geräts mit IO-Fehlern aufgrund einer nicht reagierenden/langsamen Festplatte fehlschlägt:

07/07 09:57:19.011555 0x7fd5438ffeb0:mosAsyncIO_DoIOTimedSyncIntern:01336: Time budget exceeded during IO to /dev/mapper/svm_sdz (Give-up on inflight IO)
07/07 09:57:19.011569 0x7fd5438ffeb0:mosAsyncIO_WriteZeroTimedSync:00811: mosAsyncIO_DoIOTimedSync returned ERROR, offset = 55574528, writeSize = 1048576
07/07 09:57:20.011293 0x7fd5438ffeb0:mosAsyncIO_DoIOTimedSyncIntern:01336: Time budget exceeded during IO to /dev/mapper/svm_sdz (Give-up on inflight IO)
07/07 09:57:20.011300 0x7fd5438ffeb0:mosAsyncIO_WriteZeroTimedSync:00811: mosAsyncIO_DoIOTimedSync returned ERROR, offset = 0, writeSize = 1048576
07/07 09:57:20.011304 0x7fd5438ffeb0:contDev_SendDeviceError:01632: Sending device error to MDM: DevId:97dfea7500090017 deviceName: /dev/mapper/svm_sdz readError: FALSE WriteError: TRUE
07/07 09:57:20.011471 0x7fd5438ffeb0:phyDev_InitWithBuf:02152: Io error /dev/mapper/svm_sdz, size 409600
07/07 09:57:20.011482 0x7fd5438ffeb0:contDev_SendDeviceError:01632: Sending device error to MDM: DevId:97dfea7500090017 deviceName: /dev/mapper/svm_sdz readError: TRUE WriteError: TRUE
07/07 09:57:20.015684 0x7fd5438ffeb0:contCmd_RemDevIntern:01022: DevId 97dfea7500090017 - Start rc = SUCCESS
07/07 09:57:20.015703 0x7fd5438ffeb0:contCmd_AddDev:01401: DevId 97dfea7500090017 - Done rc = TGT_ADD_DEV_IO_ERROR 

/var/log/messages zeigten, dass der HBA-Treiber Probleme mit der Festplatte, Abbrüche und Timeouts hatte:

Jul  7 09:57:15 scaleio05 kernel: mpt3sas_cm0: log_info(0x31120303): originator(PL), code(0x12), sub_code(0x0303)
Jul  7 09:57:15 scaleio05 kernel: mpt3sas_cm0: log_info(0x3112010c): originator(PL), code(0x12), sub_code(0x010c) 

Resolution

Nachdem die fehlerhafte HW ersetzt wurde, gehen Sie alle Laufwerke durch (einschließlich Root-Laufwerk: satadom):

  1. Die ersten MB des Laufwerks auf Null setzen
  2. Starten Sie den SDS-Prozess auf der SVM neu.
  3. Überprüfen, ob das Laufwerk fehlerfrei funktioniert und in CloudLink verschlüsselt wird
  4. Hinzufügen zum Storage-Pool 