NetWorker: Bandåtgärder misslyckas med felet: read open error: kommandot har slutförts (enhetsstatus är MEDIA LOAD OR MATUDECT FAILED)
Summary: Under bandetikettering eller monteringsåtgärder i NetWorker kan processen misslyckas med felmeddelandet: Read open-fel: kommandot har slutförts (enhetens status är MEDIA LOAD OR EJECT FAILED). Detta indikerar ett problem med att bandenheten sätter i eller matar ut mediet, ofta orsakat av maskinvaru- eller bandmedieproblem. ...
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
- Det går inte att märka eller montera bandvolymer med felmeddelandet:
read open error: command completed successfully (drive status is MEDIA LOAD OR EJECT FAILED) - Daemon-loggar (
daemon.raw) visar följande varningar och fel under märkning eller montering:
NSR info media warning: <device_name> opening: MEDIA LOAD OR EJECT FAILED nsrd NSR info media warning: <device_name> moving: read open error: command completed successfully (drive status is MEDIA LOAD OR EJECT FAILED) nsrd NSR warning Status update: operation 'SNMD_DEVOP_DEACTIVATE', instance '356', on device '<device_name>' has completed abnormally with status 'DEV_OP_ERROR'.
- Statuskontroll av bandenhet med hjälp av
mtKommandot visar datafel och indikerar möjliga maskinvaru- eller medieproblem:
mt -f <device_name> status <device_name>: Current Status: Data error (cyclic redundancy check). default blocksize = 65536 maximum blocksize = 524288 minimum blocksize = 1 MaximumPartitionCount = 0 EOTWarningZoneSize = 0 Error Correction Enabled CompressionEnabled Features: Performs SHORT erase operation Performs LONG erase operation Performs IMMEDIATE erase operation Can report maximum tape capacity Can report amount of tape remaining Support FIXED block length mode Support VARIABLE block length mode Returns errors on write if tape is write-protected Supports hardware data compression Can provide current absolute device block address Can provide current logical block address and partition Can physically load and/or unload tape Support PREVENT / ALLOW Media Removal Performs IMMEDIATE rewind operations Allows Setting FIXED LENGTH or VARIABLE block sizes Performs IMMEDIATE Load / Unload operations Allows hardware data compression to be enabled/disabled Can position tape to an absolute physical block Can position tape to a logical block (and partition) Can position tape to END of RECORDED DATA Can perform tape record positioning (backwards/forwards) Can perform tape file positioning (backwards/forwards) Can move backwards across records or filemarks or setmarks Can write FILEMARKS Performs IMMEDIATE tape mark write operations operation status on <device_name> failed: Data error (cyclic redundancy check). (Investigate bad media or hardware)
- Operativsystemsloggar rapporterar varningar relaterade till medieladdning eller utmatningsfel på bandenheten, till exempel:
NetWorker media: (warning) rd=dcp-nwsn1.rnp.local:\\.\Tape4 opening: MEDIA LOAD OR EJECT FAILED
Cause
Som felet antyder, problem med hårdvara (bandenhet) eller bandmedia.
Resolution
Kontrollera om problemet ligger i en specifik bandenhet eller kontrollsökväg genom att byta enhet. Maskinvaruleverantören kan ge bättre hjälp om hur du hanterar den här situationen.
Affected Products
NetWorker FamilyArticle Properties
Article Number: 000334637
Article Type: Solution
Last Modified: 18 Jul 2025
Version: 1
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.