VxRail: Kan de VMware vCenter Server niet upgraden bij het exporteren van data van bron-VM
Summary: Tijdens een upgrade van VxRail VCenter mislukte deze bij het exporteren van data van de bron-vCenter-server naar de doel-vCenter-server. Uit het logboek blijkt dat er veel tijd is besteed aan het exporteren van VMware Analytics Service-data. ...
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Van VxRail
lcm-web.log:
2025-08-31T10:27:25.367Z <4304e36e4934ff08fc8120c70e58301b> lcm [WARN] <183> VirtualApplianceUpgradeService.java runUpgrade() (1158): LCM Exception occurred during upgrade for virtual appliance 0 - {}
com.vce.lcm.exception.LCMException: Failed to upgrade the VMware vCenter Server: Failed to export data from source VM VCENTER01.
at com.vce.lcm.api.LCMServiceImpl.handleUpgradeException(LCMServiceImpl.java:2129)
at com.vce.lcm.api.LCMServiceImpl.performUpgrade(LCMServiceImpl.java:509)
at com.emc.mystic.manager.upgrade.service.VirtualApplianceUpgradeService.runUpgrade(VirtualApplianceUpgradeService.java:1134)
at com.emc.mystic.manager.upgrade.service.PureUpgradeRestServiceImpl.lambda$retryVirtualApplianceUpgrade$0(PureUpgradeRestServiceImpl.java:129)
at java.base/java.util.concurrent.Executors$RunnableAdapter.call(Executors.java:515)
at java.base/java.util.concurrent.FutureTask.run(FutureTask.java:264)
at java.base/java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExecutor.java:1128)
at java.base/java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:628)
at java.base/java.lang.Thread.run(Thread.java:829)
Caused by: com.vce.lcm.exception.LCMInternalException: Failed to upgrade the VMware vCenter Server: Failed to export data from source VM VCENTER01.
at com.vce.lcm.core.upgrade.ComponentUpgradeService.performComponentUpgrade(ComponentUpgradeService.java:339)
at com.vce.lcm.api.LCMServiceImpl.performComponentUpgrade(LCMServiceImpl.java:2439)
at com.vce.lcm.api.LCMServiceImpl.performCompositeUpgrade(LCMServiceImpl.java:1845)
at com.vce.lcm.api.LCMServiceImpl.performUpgrade(LCMServiceImpl.java:507)
... 7 common frames omitted Van de /var/log/vmware/upgrade/export.json logbestand van de nieuw ontwikkelde vCenter server, is de upgrade mislukt wanneer "Exporting VMware Analytics Service data..." met TIME_OUT Error:
{
"progress": 37,
"progress_message": {
"id": "ur.upgrade.script.export.progress.text",
"translatable": "Exporting %(0)s data...",
"args": [
"VMware Analytics Service"
],
"localized": "Exporting VMware Analytics Service data..."
},
"status": "error",
"info": [],
"warning": [],
"question": null,
"error": {
"detail": [
{
"id": "ur.upgrade.execution.timedout.text",
"translatable": "Upgrade phase timed out. The time planned for the upgrade phase was %(0)s minutes. The upgrade phase has already been running for %(1)s minutes.",
"args": [
60,
60
],
"localized": "Upgrade phase timed out. The time planned for the upgrade phase was 60 minutes. The upgrade phase has already been running for 60 minutes."
}
],
"componentKey": "upgrade_framework",
"problemId": null,
"resolution": {
"id": "ur.upgrade.execution.timedout.resolution",
"translatable": "To extend the default timeout, set environment variable %(0)s for export upgrade phase, %(1)s for import upgrade phase, and %(2)s for import historical data phase. The timeout is in minutes.",
"args": [
"UPGRADE_EXPORT_TIMEOUT",
"UPGRADE_IMPORT_TIMEOUT",
"UPGRADE_POST_IMPORT_TIMEOUT"
],
"localized": "To extend the default timeout, set environment variable UPGRADE_EXPORT_TIMEOUT for export upgrade phase, UPGRADE_IMPORT_TIMEOUT for import upgrade phase, and UPGRADE_POST_IMPORT_TIMEOUT for import historical data phase. The timeout is in minutes."
}
},Cause
Dit probleem doet zich voor omdat het push-telemetrieproces een buitensporig aantal aanvragen met unieke ID's verzendt, wat resulteert in het maken van veel bestanden in de "/var/log/vmware/analytics/prod" directory. Soms heeft dit geleid tot een accumulatie van 185.000 tot 375.000 bestanden.
Resolution
Raadpleeg KB https://knowledge.broadcom.com/external/article/322053/vcenter-server-upgrade-from-70-to-80-fai.html (Externe link)
- Maak verbinding met de bron-vCenter-server via SSH
- Voer de volgende opdracht uit om het aantal bestanden te controleren dat is gemaakt op de vCenter-server als gevolg van het push-telemetrieproces:
ls /var/log/vmware/analytics/prod | wc -l - Download de
cleaning_vddk_script.shscript uit het gedeelte Bijlagen van dit artikel. - Upload het script naar vCenter en wijs uitvoeringsmachtigingen toe met deze opdracht:
chmod +x cleaning_vddk_script.sh - Voer het script uit:
./cleaning_vddk_script.sh - Start de upgrade opnieuw vanaf de VxRail plugin.