NVP-vProxy:備份間歇性失敗,並顯示「Memory allocated failed.記憶體不足」

Summary: VMware 工作流程會在排定執行期間間歇性遇到一些隨機的虛擬機器故障,且訊息記憶體不足。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

NetWorker VMware Protection 整合是透過 vProxy 裝置進行設定。
VMware 工作流程在排定執行期間,會間歇性遇到一些隨機的虛擬機器 (VM) 故障。
後續的虛擬機器執行將成功完成。
備份工作流程記錄顯示:
YYYY/MM/DD HH:MM:SS TRACE:  [215] "Hard disk 1": VddkBlockReader: starting go routine ...
YYYY/MM/DD HH:MM:SS TRACE:  [215] "Hard disk 1": VimDiskRegionReader: starting go routine ...
YYYY/MM/DD HH:MM:SS ERROR:  [215] "Hard disk 1": VddkBlockReader: VDDK Error: 2: Memory allocation failed. Out of memory..
YYYY/MM/DD HH:MM:SS ERROR:  [215] "Hard disk 1": VddkBlockReader: failed reading from "Hard disk 1" at sector 4955136.
YYYY/MM/DD HH:MM:SS TRACE:  [215] "Hard disk 1": VddkBlockReader: sent VDDK read error on error channel.
YYYY/MM/DD HH:MM:SS INFO:   [215] "Hard disk 1": VddkBlockReader: finished go routine.

Cause

虛擬機器全都使用網路封鎖裝置 (NBD) 傳輸進行排定執行,並在排定執行期間耗盡 ESXi 主機資源。NBD 傳輸會使用網路將 VMware 變更區塊傳輸至 vProxy,且效率低於 HOTADD 傳輸。

使用的 vProxy 已啟用 NBD 工作階段 (非零值)。VM 備份會話日誌顯示使用的傳輸方法是 NBD。

Resolution

解決方案:
建議使用 HOTADD 傳輸以執行 vProxy 備份。如果需要 NBD 傳輸,則應在計劃執行期間減少 NBD 會話數。
請參閱 NetWorker VMware 整合指南 ,以瞭解相關事項 hotadd 要求。

因應措施:
將虛擬機器遷移至相同叢集中其他可用的 ESXi 主機,並執行備份。