Deployment KB: Unable to power on the VM on ESXi host in the CR Vault
Summary: During VM restore inside the cyber vault, VM restore failed to power on.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
In the /var/log/vmware.log file, similar entries to the below are seen:
Note: The log excerpts are examples. Date, time, and environmental variables may vary depending on the environment.
Unable to create virtual scsi0:0.filters="esx_splitter",
Failed to attach filter scsi0:0.filters="esx_splitter": Not found.
Failed to attach filter scsi0:0.filters="esx_splitter": Not found.
Cause
Production VM protected using RP4VM may cause issues after restore inside the vault.
This issue usually occurs if there is a splitter installed on the source ESXi host which is not present on the destination ESXi host.
This issue usually occurs if there is a splitter installed on the source ESXi host which is not present on the destination ESXi host.
Resolution
To resolve this issue, follow the steps below:
- Connect to the ESXi host the virtual machine is on using SSH and root credentials
- Navigate to the virtual machines .vmx file using this command:
cd /vmfs/volumes/datastore/virtual_machine_folder/
- Open the .vmx file with a text editor: vi virtual_machine.vmx
- Add a # before any filters that contain scsi0:0.filters="esx_splitter"
- Save the changes and exit the text editor.
- Power on the virtual machine.
Affected Products
Avamar, Cyber Recovery Series, VMware ESXi 6.xProducts
VMware ESXi 6.5.X, VMware ESXi 6.7.X, VMware ESXi 7.xArticle Properties