Avamar: Data Domain backend capacity report fails due to Physical Capacity Measurement (PCM) being disabled
Summary: The Avamar backend capacity report with Data Domain fails due to the Physical Capacity Measurement (PCM) feature being disabled.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
In the Avamar Administrator console, a report with the type "Backend Capacity (Data Domain)" fails.
The Management Console Service (MCS) logs show the following error:
The Management Console Service (MCS) logs show the following error:
/usr/local/avamar/var/mc/server_log/mcserver.log.0
08/07-11:23:45.00903 [Report-1419#523263] com.avamar.mc.datadomain.DdrRestClient$MyResponseErrorHandler.handleError
WARNING: error response body is {"details": "Feature is not enabled.", "code": 5045}
08/07-11:23:45.00903 [Report-1419#523263] com.avamar.mc.rpt.job.BackendCapacityDDReportJob.submit
FINE: Submit fail on creation, mid:null Exception:
08/07-11:23:45.00915 [Report-1419#523263] com.avamar.mc.datadomain.DdrRestClient$MyResponseErrorHandler.handleError
WARNING: error response body is {"details": "**** Invalid compression measurement ID: \"null\".", "code": 5455}
08/07-11:23:45.00915 [Report-1419#523263] com.avamar.mc.rpt.job.BackendCapacityDDReportJob.run
WARNING:
com.avamar.mc.rpt.bcrdd.DDBackendCapacityReportException:
at com.avamar.mc.rpt.bcrdd.CompressionMeasurement.deleteMeasurementById(CompressionMeasurement.java:295)
at com.avamar.mc.rpt.job.BackendCapacityDDReportJob.submit(BackendCapacityDDReportJob.java:279)
at com.avamar.mc.rpt.job.BackendCapacityDDReportJob.run(BackendCapacityDDReportJob.java:130)
at com.avamar.mc.rpt.job.ReportManager$1.run(ReportManager.java:88)
at java.lang.Thread.run(Thread.java:750)
Cause
The REST API response from the Data Domain details that a feature is not enabled.
The feature which must be enabled on the Data Domain is Physical Capacity Measurement (PCM).
{"details": "Feature is not enabled.", "code": 5045}
The feature which must be enabled on the Data Domain is Physical Capacity Measurement (PCM).
Resolution
Enable PCM on the Data Domain to take capacity measurements.
1. Log in to the Data Domain with SSH as sysadmin.
2. Run the following command to enable PCM.
1. Log in to the Data Domain with SSH as sysadmin.
2. Run the following command to enable PCM.
compression physical-capacity-measurement enable and-initialize3 Run the Data Domain backend capacity report again from the Avamar Administrator console, it may take some time.
Additional Information
See the related KB article for Data Domain capacity measurements.
000058798 | DDOS Physical Capacity Measurement or Physical Capacity Reporting Frequently Asked Questions
000058798 | DDOS Physical Capacity Measurement or Physical Capacity Reporting Frequently Asked Questions
Affected Products
Avamar ServerArticle Properties
Article Number: 000227766
Article Type: Solution
Last Modified: 03 Feb 2025
Version: 2
Find answers to your questions from other Dell users
Support Services