iDRAC: iSM 5.1.0.0 Metric Injection Feature Fails With iDRAC9 7.00.00.00 or higher
Summary: iDRAC service module (iSM) Metric Injection feature fails with iSM 5.1.0.0 and iDRAC9 firmware version 7.00.00.00 or higher.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
The Metric Injection feature in iSM 5.1 does not work and is disabled if iSM 5.1 is installed on a server with iDRAC firmware 7.00.00.00 or higher.
This is seen on Windows and Linux Operating Systems.
The Metric Injection feature in iSM 5.1 gets disabled even if it was enabled during iSM installation.
Telemetry feature enablement gives incorrect ISM0058 message, patch, get operation is failing in iSM 5.1.0.0.
This is seen on Windows and Linux Operating Systems.
The Metric Injection feature in iSM 5.1 gets disabled even if it was enabled during iSM installation.
Telemetry feature enablement gives incorrect ISM0058 message, patch, get operation is failing in iSM 5.1.0.0.
Cause
iSM 5.1.0.0 code firmware check failing for iDRAC 7.00.00.00 or higher.
Resolution
This issue was fixed in the iSM 5.2.0.0 release.
Installing the latest iSM when using the iDRAC9 firmware 7.xx.xx.xx fixes the issue.
Workaround:
Downgrade to iDRAC firmware 6.10.xx.xx for iSM 5.1.0.0.
Affected Products
iDRAC Service Module, iDRAC9 - 6.xx Series, iDRAC9 - 7.xx SeriesArticle Properties
Article Number: 000214763
Article Type: Solution
Last Modified: 10 Mar 2025
Version: 3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.