PowerProtect: OpenShift Backup Fails with Error cproxy Already Exists

Summary: Protection job fails due to "cproxy already exists" error.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

PowerProtect Data Manager protection job fails with an error message similar to the following:

Error: Unable to backup PersistentVolumeClaims. PVC backup returned with an error: Unable to backup PVC 'XXX-XXXXXXXXXXXX-XXXXX-XXXXXXXXXXXX-XXXX-1'. Unable to create Pod 'XXXXXXXXX-XXXXXXXXXX-YYYY-MM-DD-HH-MM-SS-XXXXXXXXX-XXXXXXXXXX-XXX-XXXXXXXXXXXX-XXXXX-XXXXXXXXXXXX-XXX-YYYY-MM-DD-HH-MM-SS-cproxy': pods "XXXXXXXXX-XXXXXXXXXX-YYYY-MM-DD-HH-MM-SS-XXXXXXXXX-XXXXXXXXXX-XXX-XXXXXXXXXXXX-XXXXX-XXXXXXXXXXXX-XXX-YYYY-MM-DD-HH-MM-SS-cproxy" already exists Unable to backup PVC 'XXX-XXXXXXXXXXXX-XXXXX-XXXXXXXXXXXX-XXXX-1': Unable to create pod in safeguard limit of 10 minutes.

This issue occurs when the following conditions are met:

  • There are multiple PVCs that have the same first 40 characters in their names.
  • Parallel processing of multiple PVCs is enabled.
  • PowerProtect Data Manager version 19.17.0-10 and earlier is in use.

Cause

This is a software defect. 

Resolution

This issue is addressed in the PowerProtect Data Manager version 19.17.0-18.

Affected Products

PowerProtect Data Manager
Article Properties